DETECTION FIELD ADJUSTMENT
In order to adjust the detection field, follow these steps:
The head can balance in six positions from 0º to 30º and carry out a 350º turn, moving the detection area as indicated in the diagram:
In order to check the coverage area, turn the "METER" selector to the maximum position (6m.), the "LUX" selector to the positon (á
"TIME" selectors to the minimum position (6s.)
Move about in the detection field limits to check coverage. The limits of this field can be varied with the "METER" selector.
CONNECTION INDICATORS.
There is a red LED inside the apparatus which lights up when the circuit is activated. In the DICROMAT 2, two LEDs exist: 1 red for circuit C1
and one yellow for circuit C2.
BRIGHTNESS ADJUSTMENT
The proximity switch can be adjusted in such a way that it is only switched on when the light conditions are below the selected level. Turning the
"LUX" selector to position (á
light.
In addition, the DICROMAT 2 has a second circuit (C2) which functions independently of the light conditions.
DISCONNECTION DELAY ADJUSTMENT
Turning the "TIME" selectors, the disconnection delay of the circuits is adjusted.
), it will react under any light conditions. Turning it only towards the ( á ) position, it will react in conditions of low
Circuit
C1 (L – L1)
TIME (6s. – 12m)
C2 (T1 - T2)
DICROMAT
TIME 1 (6s. – 12 min.)
TIME 2 (10s. – 30 min.)
Red LED
DICROMAT 2
Red LED
Yellow LED
) and the