Unscrew the terminal covers from the power supply module and connect the sensor according to the colour code.
Connect the power supply and charge according to the following diagrams:
L
N
DICROMAT
Carefully check the connections carried out.
Screw back the terminal covers.
Fix the supply module into the drill hole in the ceiling.
Fix the sensor into the ceiling. Place the long sidepieces inside the hole in the ceiling, keeping the short sidepieces out of it against the surface
of the ceiling. Press hard until the edge of the sensor is fitted into the ceiling.
STARTING IT UP. ADJUSTMENTS.
The DICROMAT is supplied with a detection area limiter that must be removed if a detection area of 360º is required or a 6m. diameter area
detected at a 2.4m. height. The device is divided into 12 sectors of two heights. Each sector blocks a 30º area. The complete area limiter limits
the detection area to a 1.5m. diameter zone. Removing the inner ring, a 4m. diameter detection area is achieved and eliminating the outer ring,
a 6m. diameter detection area is achieved.
Cut the accessory according to the detection area required and place it on the DICROMAT lens.
Levering open with a small screwdriver the slot marked " OPEN", we access the adjustment selectors and can vary the detection angle.
N
BLACK
L
RED
T1
YELLOW
T2
TIME1
12m.
6s.
3m.
5m.
L
N
VENTILATIÓN
HEATING
TV C.C.
SUPPLY
DICROMAT 2
TIME2
30m.
10s.
á
30
15m.
BROWN
L1
N
C1
BLACK
L
RED
T1
C2
T2
YELLOW
LUX
METER
á
6m
1m
4m