Tallas D-EBOOST 850 Instrucciones De Instalación Y Mantenimiento página 8

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Function
Auto Mode
Manual mode
Anti-leakage
Cut in
Cut out
Max pump on
(B) MODE selection button
Selectable modes:
1) AUTO_MODE;
2) MANUAL_MODE;
3) ANTI LEAKAGE;
4) CUT_IN;
5) CUT_OUT,
6) MAX_PUMP_ON;
To unlock the choice of function press "MODE" button for 5 seconds.
Press "MODE" to scroll through the various operating modes (AUTO_MODE or MANUAL_MODE) or parameters to be
modified (CUT IN and CUT OUT) or to enable certain functions (ANTI-LEAKAGE and MAX PUMP ON). While scrolling
through the modes, the LED of the function selected will flash. On returning to AUTO_MODE the active functions will be
highlighted by the relative LED lighting up with a steady light. See paragraph 2 (Description of the functions).
Indicators on "MODE"
AUTO MODE: the pump will work in automatic mode see 9.2.1
MANUAL MODE: the pump works in manual mode see 9.2.1, and the user can decide when to switch it on or off by acting
on the "SET" button. SET-ON switched On SET-OFF switched Off.
CUT-IN: pressure setting (always enabled) minimum pressure below which the pump is activated, can be set between 1.5
and 3.0 bar, factory setting 1.8 bar; the pump is activated even if the flow is less than a minimum value of 1.5 l/min, factory-
setting.
CUT-OUT: pressure setting (disabled by default) above which the pump stops, the factory setting for "CUT-IN" + 1 bar
(1 Led enlighted), but can be increased up to 3.5 bar (50.8 psi).
To enable it select the function by pressing "MODE" until the LED corresponding to CUT-OUT flashes then:
press SET for 10 seconds to unlock the function (now the led lights on the pressure values are switched on),
1)
2)
press SET to select the required value
To disable the function, position the cut-out value on 0 [bar or psi]
3)
exit the setting by pressing MODE
4)
Display configuration
,
.
ENGLISH
Set
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
Increase/Decrease
Increase/Decrease
OFF: disabled
ON: enabled
OFF: disabled
5
Alarm Reset
Press SET
Press SET
.