INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and the
fixture operate at high temperatures.
• Keep fixture at least 2" (51 mm) from combustible
materials. Do not aim at objects closer than 3' (1 m).
• Use only T4 100W (max.), G8 tungsten halogen bi-
pin 120 VAC lamps.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
Swing the sensor head towards the clamp
screw joint.
Clamp Screw
Rotate the sensor head clockwise 180° so the
controls face down.
Controls
If the sensor pops out of the ball joint, loosen the clamp
screw and push the sensor back into the ball joint.
Tighten the clamp screw when done.
Bulb installation.
NOTE: When re-lamping, turn power off and let the
fixture cool.
To remove lamp shade, loosen set screw 2 full turns
with a small flat-head screwdriver. Turn shade
counterclockwise and remove.
To remove bulb, pull straight out of fixture.
To replace bulb, push bulb pins into lamp socket.
Check that the bulb is seated properly.
To reinstall lamp shade, place shade on fixture and
align notches on shade with tabs on fixture. Turn
clockwise. Tighten set screw firmly.
W
L
C
IRE THE
IGHT
ONTROL
Turn power off at the fuse or circuit breaker.
Remove the existing light fixture.
Controls
Controls
.
Install mounting strap to junction box using screws
appropriate for your junction box.
The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger can
be threaded through the hole in the center of the
cover plate. The small end then goes into one of the
slots on the mounting strap.
Route all fixture wires through the large holes in the
gasket as shown.
Connect the junction box wires to the light fixture
wires as shown. Twist together and secure with
wire connectors.
Black to
Mounting
Black
Strap
Junction box ground wire to
green ground screw on fixture.
M
L
C
OUNT THE
IGHT
ONTROL
Place the Mounting Bolt through the front of the
junction box cover. Push the small gasket hole over
the Mounting Screw.
Make sure the wire connectors and wires are inside
the junction box. Align the Mounting Screw with the
center hole in the Mounting Strap. Secure the fixture
to the Mounting Strap.
Push the Rubber Plug firmly into place.
If a wet location junction box was not used, caulk the wall
plate mounting surface with silicone weather sealant.
Lamp shade
Lock nuts
Keep lamps at least 2" (51 mm) from the
sensor and 2" (51 mm) from combustibles.
Adjust the lamp holders by loosening the lock nuts,
but do not rotate the lamp holders more than 180°
from the factory setting.
Adjust lamp shades by loosening the set screws
several turns, turn shades counterclockwise and
remove. Reinstall the shades in the desired position
and tighten set screws.
White to
White
Rubber Plug
Mounting Bolt
Gasket
.
Set screw