INSTALLING THE BOILING CHAMBER
Your distiller has been shipped with the boiling chamber already in place. If it has
been disturbed during shipping follow the simple steps listed below to reinstall
the boiling chamber.
CAUTION: To avoid personal injury or property damage, be certain distiller
is unplugged.
1) Place the hook of the boiling chamber over the lift spring bracket located in
the front half of the distiller.
2) Be sure the gasket is securely in place over the top rim of the boiling chamber.
3) Fit the lid with the attached tubes over the gasket and onto the boiling
chamber making sure that the threaded center support protrudes through
the hole in the lid. Ensure that the tubes are centered in the distiller openings.
4) Secure the lid by turning the cover knob clockwise.
5) Make sure that the boiling chamber moves freely up and down by pressing
down on the top of the boiling chamber. The boiling chamber should lift
when it is released. If the boiling chamber does not move freely, recheck all
connections.
6) Fully insert the boiling chamber power cord into the receptacle. A loose
connection may damage the power cord and result in failure of the
distiller. Be sure the plug is fully inserted into the socket.
Lift Spring Bracket
Hook
Gasket
Boiling Chamber Lid Knob
12