Tabla De Contenido; Applications; Pumpable Liquids - Tallas D-JET Serie Instrucciones De Instalación Y Mantenimiento

Tabla de contenido
INDEX
1. APPLICATIONS ........................................................................................................................................... 1
2. PUMPABLE LIQUIDS .................................................................................................................................. 1
3. TECHNICAL DATA AND LIMITATIONS OF USE ...................................................................................... 2
4. MANAGEMENT ............................................................................................................................................ 2
4.1
Storage ................................................................................................................................................ 2
 
4.2
Transport ............................................................................................................................................... 2
 
4.3
Weight and dimensions ....................................................................................................................... 2
 
5. WARNINGS .................................................................................................................................................. 2
6. INSTALLATION ........................................................................................................................................... 3
7. ELECTRICAL CONNECTION ...................................................................................................................... 3
8. START-UP .................................................................................................................................................... 3
9. PRECAUTIONS ............................................................................................................................................ 4
10. MAINTENANCE AND CLEANING ............................................................................................................ 4
10.1 Cleaning the suction filter ..................................................................................................................... 4
10.2 Cleaning the NRV ................................................................................................................................. 4
11. TROUBLESHOOTING ............................................................................................................................... 4
12. GUARANTEE ............................................................................................................................................. 5
WARNINGS
Read all this documentation carefully before installation:
Take out the plug before any intervention. Absolutely avoid dry operation: the pump must be
activated exclusively when it is immersed in water. If the water is finished, the pump must be
deactivated immediately, taking the plug out of the socket.
Protect the electropump against inclement weather.
The pump is equipped with a thermal overload safety device. In the event of any overheating of
the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20
minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is
essential to identify and deal with the cause of the overheating. See Troubleshooting.

1. APPLICATIONS

Self-priming centrifugal jet pumps with excellent suction capacity, even when gas is present in the water. Particularly
indicated for water supply and pressure boosting in farmhouses. Suitable for small farming and gardening applications
and for general hobby activity. Thanks to their compact and handy shape, they are also used for particular applications
as portable pumps for emergency situations such as for drawing water from tanks or rivers.
These pumps cannot be used in swimming pools, ponds or basins where people are present, or for
pumping hydrocarbons (petrol, diesel fuel, combustible oils, solvents, etc.) in accordance with the
accident-prevention regulations in force. They should be cleaned before putting them away. See the
chapter "Maintenance and Cleaning".

2. PUMPABLE LIQUIDS

Clean, free from solid bodies or abrasive substances, non-aggressive.
Fresh water
Rainwater
(filtered)
Clear waste water
Dirty water
Fountain water (filtered)
River or lake water (filtered)
Drinking water
Suitable
Not suitable
o
ENGLISH
o
o
1
Table1
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Tabla de contenido
loading

Este manual también es adecuado para:

P1-650wP1-850wP1-1.100w