10- Unlocking The Actuator; 11- Electrical Wiring Harnesses - Elvox EKKO EAM2 Manual Para El Conexionado Y El Uso

Actuador para cancelas batientes 24 vdc
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
EKKO
Unlocking the actuator:
open the sliding door (A), insert the key, turn it anticlockwise (B) and remove the cover (C).
Turn the unlocking lever 180° anticlockwise.
With the actuator unlocked, manually simulate opening and closing completely. There must be no strong mechanical friction during this movement.
N.B.: Check for the presence and tightness of the mechanical stops on both opening and closing. Should the gate leaf exceed a length of 2 metres it is
necessary to install the electrical lock.
Electrical wiring harnesses:
Open the cover of the compartment for the electrical wiring harness, take out the terminal block and do the wiring according to the diagram:
Terminal number
1
2
3
4
5
The electrical wiring between the control unit and the actuator must not exceed 15 metres.
EN
B
A
Wire colour
Unleaded
White
Red
Brown
White
C
Description
Encoder signal
Encoder supply voltage negative (GND)
Encoder supply voltage positive (+12 Vdc)
Motor supply voltage (closing)
Motor supply voltage (opening)
13
Tabla de contenido
loading

Este manual también es adecuado para:

Ekko eam3

Tabla de contenido