EKKO
Standard system setup
2x0,5 mm
2
Technical data:
Description
Electric motor power supply
Electric motor maximum absorption
Electric motor maximum power
Maximum gate leaf length
Maximum gate leaf weight
Maximum opening
Opening time
Protection rating
Operating temperature
Dimensions
Weight
Frequency of use
Useful travel
Dimensions and clearance of actuator EAM1 and EAM2:
105 mm
Limitations of use EAM2:
Length of gate leaf (metres)
Limitations of use EAM3:
Length of gate leaf (metres)
EN
E
A
2x2,5 mm
+3x0,5 mm
(encoder)
2
2
20 mm
1.5
2
2.5
3
2.5
3
3.5
4
2x1 mm
G
3x0,5 mm
E
2x0,5 mm
2
4x0,5 mm
A
2x2,5 mm
+3x0,5 mm
(encoder)
2
2
D
EAM2
24 Vdc
5 A
120 W
3 metres
300 kg
110°
Min. 10sec. Max 22 sec.
IP44
From -20 to +55°C
785x110x105 mm
9.2 kg
100%
280 mm
EAM2 785 mm
EAM3 925 mm
C
2
Key
A - Linear actuator
F
B - Control unit
C - Flashing light
2
D - 2-channel radio control
E - Pair of photocells
F - Selector
B
2
G - Electrical lock
3x1,5 mm
2
230/120 Vac
EAM3
24 Vdc
5 A
120 W
4 metres
250 kg
110°
Min. 15sec. Max 25 sec.
IP44
From -20 to +55°C
925x110x105 mm
10.2 kg
100%
430 mm
Weight of gate leaf (kg)
800
550
400
300
Weight of gate leaf (kg)
550
400
300
250
18 mm
9