G
B
D
- MANNED POSITION OPERATION
In such mode the remote control will not operate.
Set DIP1 on ON the LED DL1 starts flashing. Flashing will end within 1
minute, unless any operation is initiated.
To operate the fence depress and maintain the pushbutton "K Button".
In case the pushbutton is released the fence stops. Further depressing
the pushbutton will command motion of the fence in the opposite direction.
While working safety features (photocells and safety strip) are overriden.
E
- TIME SETTING
Setting must be performed with the fence fully closed, with STROKE
END SWITCHES SET.
1 - Put DIP 2 in the ON mode => the LED DL1 emits short blinkings.
2 - Depress the pushbutton PROG => the fence opens
3 - After 2 seconds from the fence reaches the full open position,
depress the pushbutton PROG to set the operation time of the
fence.
4 - Wait as long as you want the shutter to remain open before the
automatin closing (excluded by DIP3 OFF).
5 - Push the button PROG. to command the shutter closing, also the
pause time count before the automatic closing stops - max. 5 minutes
(the LED DL1 stops flashing). On triggering of close stoke end switch,
the fence stops.
6 - AT THE END OF THE PROGRAMMING PUT THE DIP 2 BACK ON
OFF. DURING THE PROGRAMMING THE SAFETIES ARE ACTIVE
AND THEIR INTERVENTION STOPS THE PROGRAMMING (THE
LED DL1 WHICH WAS LIGHTENING NOW HAS A COSTANT
LIGHT). TO REPEAT THE PROGRAMMING SET THE DIP 2 ON
OFF), CLOSE THE DOOR FOLLOWING THE PROCEDURE "C -
CHECKING THE ROTATION DIRECTION OF THE MOTOR" AND
REPEAT THE PROGRAMMING DESCRIBED ABOVE.
F
- RADIO CODE LEARNING PROCEDURE (CRX MODELS ONLY)
The position of the door does not affetc the code memorisation.
1 - Set DIP 1 - ON and subsequently DIP 2 - ON => DL1 programming led
will lighten for 10 seconds, witch is the time required for they code's
programming.
2 - Following code setting through DIPs inside the remote control, repress
the remote control button (normally the A channel) within the 10 set
seconds. If the remote control is correctly matched, the DL2 green led
flashes shortly.
3 - The codes' programming time is automatically renewed to read in the
following remote control.
4 - To end the programming wait 10 seconds, or press for a while the
PROG. button => DL1 programming led will stop lightening.
5 - Re-set DIP 1 - OFF and DIP 2 - OFF.
RADIO CODES CANCELLATION PROCEDURE
The position of the door does not affetc the code memorisation.
1 - Set DIP 1 - ON and subsequently DIP2 - ON => DL1 programming
led will lighten with a frequency of 1 sec. ON and 1 sec. OFF for 10
seconds.
2 - During the 10 seconds => press and keep pressed the PROG. Button
for 6 seconds => the memory cancellation is signalled by two flashings
of the DL2 green Led.
3 - Subsequently DL1 programming led stays active and it is possible to
add new codes following the procedures described above.
4 - Re-set DIP 1 - OFF and DIP 2 - OFF.
MEMORY SATURATION SIGNALING
The position of the door does not affect the code memorisation.
1 - By setting DIP 1 - ON and subsequently DIP 2 -ON.
2 - DL2 green Led lightens for 6 times thus signalling that the memory is
full (60 codes available).
3 - Subsequently the DL1 programming led stays active for 10 seconds,
thus enabling the possible total cancellation of the codes.
4 - Re-set DIP 1 - OFF and DIP 2 - OFF.
O
PERATION OF THE OPERATING ACCESSORIES
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE
CONNECTED.
Make sure that any other type of command accessories (e.g. mass
detectors) used on the installation are set in the IMPULSIVE mode,
otherwise, the rolling shutter will be operated even without the
protection of the safety devices.
OPERATION BUTTON (COM-K BUTTON)
If DIP6 is ON => It cyclically commands open-stop-close-stop-open-
etc.
If DIP6 is OFF => It opens the door when this is closed. If it is operated
while the door is opening, it has no effect. If it is
operated when the door is open, it closes the door
and, if it is operated while the door Is closing, it opens
the door again.
CLOCK FUNCTION
If you want the Clock Function must request J with firmware 02.
ATTENTION: A CLOCK CONNECTED TO J with fw 03 or more
ACTIVATES THE AUTOMATIC MOVEMENT OF THE AUTOMATION
WITHOUT HAVING THE PROTECTION OF THE SAFETY DEVICES!
The Clock Function is useful In the rush hours, when vehicle traffic is slow
(e.g. entry/exit of workers, emergencies In residential or parking areas
and, temporary, for removals).
CLOCK FUNCTION APPLICATION
It is necessary to request a J control panel with firmware 02.
Select the automatic functioning DIP 6 OFF.
By connecting a switch and/or a daily/weekly timer (in place or in parallel
with the opening button N.O. "COM-K BUTTON"), it is possible to open
the automation or to keep It open, as long as the switch is on or the timer
is activated.
When the automation is open, all operating functions are inhibited.
On switch release, or at set time, the actuator will close.
RADIO TRANSMITTER
If DIP6 is ON => It cyclically commands open-stop-close-stop-
open-etc.
If DIP6 is OFF => It opens the door when this is closed. If it is operated
while the door is opening, it has no effect. If it is
operated when the door is open, it closes. If it is
operated while the door is closing, it opens the door
again.
S
AFETY ACCESSORIES OPERATION
PHOTOCELL (COM-PHOT.) DIP4
If DIP 4 is OFF => The door does not open if there is an obstacle within
the photocells range of action. During operation,
photocells work both when the door opens (by
starting the opening movement again after half a
second time), and when it closes (by starting the
reverse movement after one second time).
If DIP 4 is ON =>
If there is an obstacle within the photocells range
of action when the door is closed and its opening
is commanded, the door opens (during its opening,
photocells do not work). Photocells work only while
the door is closing (by starting its reverse motion after
one second, even if they are still engaged).
NOTE: in case this line is not used, bridge the contacts COM-PHOT.
SAFETY STRIP (EDGE - COM)
During the opening it's not active.
During the closure, if committed, reverses the opening movement.
If during the closing acts for a second time, running a small reversion of 1
second and signals the alarm of fails or involved safety strip (contact NO).
18
18
18
18