TRZ 12-2
3.3.2 Entering the heating pro-
gramme (groups P1...P6)
Up to 6 groups can be programmed,
each with a heating or economy mode
starting time and an allocated tempera-
ture (for factory defaults for groups
P1..P6 refer to table in Appendix).
In the default setting, groups P1 and
P2 are active.
Avoid time overlaps.
i
Activating/deactivating groups
Press the Prog button (5) repeatedly
B
until the desired group appears.
Press the Set button (17) so that the
B
group number (1...6) stops flashing
(= ON) / starts flashing (= OFF).
If desired: select another group.
B
Press the Prog button (5) repeatedly
B
until SEt appears.
Press the Set button (17) to store
B
the active group settings.
Changing the basic setting
Press the Prog button (5) repeatedly
B
until the desired group appears.
Press and hold the Day button (4)
B
and set the days of the week (1...7,
1-5, 6-7 or 1-7) by pressing the
/
buttons.
12
Press and hold the Hour button (3)
B
or the Minute button (2) and use the
/
buttons to set the start time
for heating/economy mode.
Set the temperature using the
B
/
buttons.
Press the Prog button (5) repeatedly
B
until SEt appears.
Press the Set button (17) to store
B
the settings.
3.3.3 Entering the holiday pro-
gramme
Press the Holiday button,
B
The hour display will start flashing.
Press and hold the Day button (4)
B
and set the number of days until the
holiday programme is to start by
pressing the
99 days – the programme starts at
midnight, so you should not include
today).
The minute display will start flashing.
Press and hold the Day button (4)
B
again and set the number of days
holiday by pressing the
tons (max. 99 days – the programme
ends at midnight, so you should only
count the day of your return if you
don't want the heating to come on
on that day).
Set the temperature using the
B
/
buttons.
, (18).
/
buttons (max.
/
6 720 610 625 (01.11)
but-