Technical data
Angle of detection: horizontal – 140°, vertical – 30°
Recommended installation height: 1-1,8m
Material: plastic
Switching element: TRIAC
Notice
Before using, check the product and make sure that it is not damaged, otherwise do not use it. Before any manipulation
make sure that mains electrical supply is disconnected. In case of damage do not repair or disassemble the product. The inco-
rrect function of the product can be caused by interruption of electromagnetic field, small temperature difference between
moving object and surroundings, reflection (e.g. strong luminous source).
Infringement of any mentioned instruction can cause harm to health or property.
Installation
1
2
35mm
56mm
230V
MAX
~50Hz
2,2A
3
4
PIR SENSOR
MICROPHONE
L
N
FUNCTION SWITCH
SENS
IP20
30~90dB
Principle of PIR sensor
PIR sensor receives infra-red waves emitted by objects in reach radius. With movement in the detection area sensor notices the change
and initiates trigger order „Light on" for adjusted time.
Reach setting (sensitivity) – SENS (5-9m (±1m))
Reach is to be understood as the area traced out by angle of detection and min. to max. available distance from sensor. Reach
can be changed by knob.
Time setting (switch-off delay) – TIME (10s (±5s) to 7min (±2min))
The countdown of adjusted time begins after last detected movement. We recommend setting the function on minimum
during functional test.
Twilight setting (response threshold) – LUX (5–2000lx)
We recommend setting the function on maximum during test.
Regulation of sound sensitivity – MIC (30-90dB)
We recommend setting the function on maximum during test.
Function
ON – sensor is in mode of constant lighting
OFF – sensor is switched OFF
PIR – sensor is in mode PIR – it is possible to set LUX, SENS, TIME
PIR+MIC – Sensor switches on based on the currently set LUX value. It also reacts to sounds (eg. clapping). It is possible to set TIME,
SENS, LUX and MIC.
Stated information may differ according to position and installation height.
Position marked - or applies to minimum and position marked
Warranty voids if the product is mechanically damaged or connected unprofessionally.
6
SENS
MIC
TWILLIGHT SENSOR
TIME
INDICATING LED
LUX
3A 250VAC
All right reserved.
SL2150
˚C
TIME
LUX
40-500W
-20~40˚C
2x1,5mm
2
or
applies to maximum.
+
7
9 m
5 m
5 m
9 m
9m
5m
0,8m
Technical data can be changed without previous notice.
UM_SL2150_150609
0,110kg
0m