Kenmore HE2Plus Serie Manual De Uso Y Cuidado página 6

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Selecting theproper location f oryour w asher improves
performance
andminimizes noise a ndpossible washer "walk."
Your washer canbeinstalled under acustom counter, orina
basement, laundry room, closet, orrecessed area. S ee "Drain
System."
Companion appliance location r equirements
should a lso be
considered. Proper installation isyourresponsibility.
You will need
A water heater set to deliver 120°F (49°C) water to the washer.
A grounded electrical outlet located within 6 ft (1.8 m) of
where the power cord is attached to the back of the washer.
See "Electrical Requirements."
Hot and cold water faucets located within 4 ft (1.2 m) of the
hot and cold water fill valves, and water pressure of
20-100 psi (137.9-689.6
kPa).
A level floor with a maximum slope of 1" (2.5 cm) under entire
washer. Installing the washer on soft floor surfaces, such as
carpets or surfaces with foam backing, is not recommended.
A sturdy and solid floor to support the washer with a total
weight (water and load) of 400 Ibs (180 kg).
Do not operate your washer in temperatures
below 32°F (0°C).
Some water can remain in the washer and can cause damage in
low temperatures.
Installation
clearances
The location must be large enough to allow the washer door
to be fully opened.
Additional spacing should be considered for ease of
installation and servicing. The door opens more than 90 °, and
it is not reversible.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the washer is
recommended
to reduce noise transfer.
Companion appliance spacing should also be considered.
Washer Dimensions
501/4"
(127.6crn)
27"
(66.6 crn}
Recommended
installation
spacing for custom
undercounter
installation
The dimensions
shown are for the recommended
spacing.
Custom undercounter
installation - Washer only
(
37" rnin,
(93.9crn)
1" _i_-_,. 27"-+_
1"
(2.6 crn}
(68,6 cm)
(2,5 cm)
Recommended
installation
spacing for recessed or
closet installation,
with or without
a pedestal
The dimensions
shown are for the recommended
spacing.
Recessed area or closet installation
--_1 1" I_- 8ov_" _ 1 _" I*-
(2.6 crn)
(77.6 cm)
(10.2 crn)
A
48 in.2
(310crn2)"
24in.2..._
(166crn2)
B
A. Side view - closet or confined area
B. Closet door with vents
* Min. top and bottom air openings for closet door.
Recessed or closet installation - Washer on pedestal
36"
(91.4cm)
Door is not reversible.
1" -_1 I_-
27" _
I_-
1"
-_41"_
30v_" _ q _" I_-
(2.5 cm)
(68.6 cm)
(2.6 cm}
(2.5 cm)
(77.5 cm)
(10.2 cm)
A
B
A. Recessed area
B. Side view - closet or confined area
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

He2plus 110.4751 serieHe2plus 110.4753 serieHe2plus 110.4754 serie

Tabla de contenido