Change load output
settings.
Press the MENU
button
for several seconds until
the number flashes.
H
The load can switched on and off by the
L
Load D2D
Load will switch on at sunset and switch off at sunrise.
L01-L23
The load output will switch on after sunset and switch off after 1-23
hours.
24H
The BlueSolar PWM Charge Controller will continuously supply
power to the load.
Press MENU
to enter
the next display
(Note: the Phoenix
VE.Direct inverters can be
controlled by connecting to
the left side connection of
the remote control to the
load output)
Press MENU
to enter
the next display
5
PV Voltage display: PV voltage and the state of charge of
the battery.
Press MENU
to enter next display.
Charge current display: PV to battery current and the state
of charge of the battery.
Press MENU
Load output settings.
The factory setting is 24h (load output always on)
to enter next display.
Load output setting.
See table below.
Load on/off switch
Trigger level
When the BlueSolar PWM Charge Controller
is set to L01-L23 the solar panel voltage will
be measured to decide whether it is night or
day to switch the load on or off.
The factory setting is 4V.
Trigger delay time
When the BlueSolar PWM Charge Controller
measures a solar panel voltage lower than
the trigger value it will delay for 10 seconds
and measure again to make sure night falls.
Factory setting: 10 seconds
.