Astralpool 33556 Manual De Instalación Y De Mantenimiento página 32

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

From this point the ozonated air exits the chamber through an automatic bleeder valve that allows only the air to flow
through, but not the water (see Figure 11). This purged air then flows to the ozone destructor where it is eliminated by the
catalytic effect of the activated charcoal in the destructor.
The off-gassing chamber is equipped with a level tube for constant visualization of proper operation. The level tube is
made of plastic (PVC glass) with a diameter of 20 mm and has three levels. The first level is the OK level, which is the
optimal operating level. The second level is the maintenance level, which is the minimal working level of the equipment
for the water in the chamber when it is running continuously. Lastly, the third level is the alert limit. When this level is
reached, the bleeder valve and other fittings should be checked, as this level warns the user that the system is not
working properly.
FIG. 11
Off-gassing chamber
OFF-GASSING
CHAMBER
LEVEL PIPE
PVC-GLASS
D20 mm
Pipe PVC-GLASS
D 32 mm
13
Ozone destructor
Ref.: Ozone generator-AstralPool-gb-R11

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

33557335583355933560

Tabla de contenido