Getting started
When the pump is blocked because of the safety mechanism, LED (1A) is
shut off, and the LED (1B) is lightened.
Pump can be restarted once by pressing on the switch (1).
After this start, if default is still there, the pump blocks itself once again,
and it is not possible to restart it. It is necessary to unplug the pumps
before trying to start it again.
SPRING 1300E : Change from manual to
piloted mode
SPRING 1300E can be used in 2 modes:
-
Mode 1 : the pump starts and stops manually, by pressing the
switch (1)
-
Mode 2 : the pump must be plugged to a pressure switch. This
pressure switch pilots the pump, managing starts and stops.
Switching from 1 to mode 2:
When the pump is on, press the switch (1)
during 5 seconds
LED (1A) is changing from green to blue color
Switching from 2 to mode 1:
When the pump is on, press the switch (1)
during 5 seconds
LED (1A) is changing from blue to green color
Pump records the last mode used.
You can unplug the pump when you don't use it. The last
mode used is memorized for the next start