PROHEAT II SERIES · AIR/WATER SYSTEM
F44
Water pump running time
Discharge water
F45
protection
F46
Flow switch
F47
Thermal fan
Buzzer alarm sound
F50
duration
Min. Ambient temperature
F71
for electrical resistance to
switch on
Maximum difference
F72
between water inlet and
outlet temperatures
Calibration of the water
Alarm
F73
inlet temperature probe.
Calibration of the water
F74
outlet temperature probe.
1# Calibration of the
F75
defrost 1 temperature
probe
2# Calibration of the
F76
defrost 2 temperature
probe
Calibration of the ambient
F77
temperature probe
Calibration of the
F78
compressor 1 discharge
temperature probe
Calibration of the
F79
compressor 2 discharge
temperature probe
F80
Password
System
settings
F81
Temperature units
F85
Display hours of service
© FLUIDRA 2016 ALL RIGHTS RESERVED. PROPRIETARY DOCUMENT.
0 – 99
5
min
90–135
115
°C
0 - 1
1
0 - 1
1
0-606
0
sec
°C
-10 - 20
12
0 – 20
3
°C
-20 – 20
0
°C
-20 – 20
0
°C
-20 – 20
0
°C
-20 – 20
0
°C
-20 – 20
0
°C
-20 – 20
0
°C
-20 – 20
0
°C
0 - 999
0
-
0/1
0
-
-
-
Time
ENGLISH
Compressor discharge
temperature
1:Enabled
0:Not enabled
1:Enabled
0:Not enabled
0: Alarm without sound
606: The alarm sound is
activated until a key is
pressed
If the electrical
resistance is available
Adjust the temperature
probe (calibration)
Adjust the temperature
probe (calibration)
Adjust the temperature
probe (calibration)
Adjust the temperature
probe (calibration)
Adjust the temperature
probe (calibration)
Adjust the temperature
probe (calibration)
Adjust the temperature
probe (calibration)
0. No password
000. Delete password
0:Centigrade
1:Fahrenheit
Pag: 20