Light is switched on independently of the
brightness for the set follow-up time.
When motions are detected, the follow-up time
is restarted.
Configuring the controller
The controller has one adjuster each for the
brightness threshold, the follow-up time and the
operating mode.
(7) Adjuster for brightness threshold, LUX
(8) Adjuster for operating mode, TEST, ON
(9) Adjuster for follow-up time, TIME
Switch on test operation
In test operation the motion detector operates
independently of the brightness. The follow-up time
is approx. 1 second. The motion detector switches
on cyclically as long as there is movement in the
detection area.
o
Turn adjuster for operating mode (8) to TEST
position (Figure 2).
i The adjusters TIME and LUX have no function
in test operation.
L'éclairage est activé en fonction de luminosité
pendant le temps de commutation réglé.
Les mouvements détectés recommencent le dé-
compte du temps de commutation.
Configurer le détecteur
Le détecteur est équipé d'un sélecteur du seuil de lu-
minosité, du temps de commutation et du mode de
fonctionnement.
(7) Sélecteur de la luminosité, LUX
(8) Sélecteur du mode de fonctionnement, TEST,
ON
(9) Sélecteur du temps de commutation, TIME
Activer le mode test
En mode test, le détecteur de mouvement fonctionne
sur la base de la luminosité. Le temps de commuta-
tion s'élève à env. 1 seconde. Tant que des mouve-
ments sont enregistrés dans la zone de détection, le
détecteur de mouvement s'active par cycle.
o
Tourner le sélecteur du mode de fonctionnement
(8) sur la position TEST(figure 2).
i Les sélecteurs TIME et LUX ne sont affectés
d'aucune fonction en mode test.
11