Stagnoli H230 Manual Del Usaurio página 27

Idiomas disponibles
  • ES

Idiomas disponibles

en
(encoder operation)= runs the operation of the motor with encoder. This fun-
GB
ction can be activated if there is the relative sensor applied on the motor shaft. The
encoder allows inverting the manoeuvre in case of obstacles and an extremely
precise operation of the slowing down processes.
en=0
encoder not activated.
en=1
encoder activated.
ss
(soft start)= allows the motor to undertake a soft start and without an initial
starting point to diminish stress of the mechanical parts of the system. Activating
this function, the motor delivers less power in its starting phase.
ss=0
function not enabled.
ss=1
function enabled.
oc
(open/close function)= the START terminal input becomes OPEN and the
PEDESTRIAN terminal input becomes CLOSE. In this mode one control opens
the gate and another closes it without intermediate stops. The PEDESTRIAN and
START functions can be activated with the radio control on the fi rst and second
channels respectively.
oc=0
function not enabled.
oc=1
function enabled.
it
(total inversion)= activating this function (with
tor encounters an obstacle in the opening or closing phase, it inverts the motion
and reaches the limit stop. If the function has not been activated, when the motor
encounters an obstacle in the opening or closing phase, it inverts the motion by
50cm before it stops.
it=0
function not enabled.
it=1
function enabled.
2b
(two safety ribs)= Operates with two safety ribs 8k2 connected in parallel.
2b=0
function not enabled.
2b=1
function enabled.
cf
(operation of the fi xed code integrated receiver)=
rolling codes.
cf=1
receiver functions with fi xed codes.
Functioning with receiver fi xed codes or rolling codes can also be seen on the
initial page of the display, where
f-00
functioning with fi xed code.
al
(alarm)= Alarm signalling that the gate has remained open. This function
activates the SCA output after 20 seconds have passed from the end of the time
regulated by
al=0
function not enabled.
al=1
function enabled.
N.B: By activating the function
Cancel
reset parametri
27
ttca
and the gate is still open.
al
(reset parameters)= to cancel the regulation parameters and
en
r-00
indicates the rolling code functioning and
re
, the
one cannot be activated.
function activated), if the mo-
cf=0
receiver functions with
loading

Productos relacionados para Stagnoli H230