START, activated while the gate is opening, will stop the gate and the
GB
matic closing time will be loaded.
ba
(blocks impulses during opening)= the station ignores the START impulses
during the opening phase.
ba=0
function not enabled.
ba=1
function enabled.
bp
(blocks impulses during pause)= the station ignores the START impulses during
the pause between opening and automatic closing (
bp=0
function not enabled.
bp=1
function enabled.
These functions are useful when there are various passages with different inputs
through the same entry point.
cr
(rapid closing)= if there is a passage through the photoelectric cells during the
opening phase, the regulation time
automatically reduced to 3 secs.
cr=0
function not enabled.
cr=1
function enabled.
2p
(open/close operation)=
movement of the gate changes direction (OPENING - CLOSING).
2p=0
function not enabled. the gate movement sequence becomes OPENING -
CLOSING (
pl
(prefl ashing)= after the START signal, the fl asher or courtesy light activates for
two seconds before the opening or closing phase begins.
pl=0
function not enabled.
pl=1
function enabled.
sv
(suction lock)= activating this function the N.O. exit always has the contact
closed, except for the time regulated by the parameter trel as from the start of the
motor movement. This mode runs the operations of a suction electrolock.
sv=0
function not enabled (the N.O. contact is activated only for the
sv=1
function enabled (the N.O. contact is always active and it deactivates only
trel
for the
re
(energy saving)= keeps the photoelectric cells off while the system is not active
permitting energy saving. The photoelectric cells therefore remain active only whi-
le the gate is in movement and for four seconds after the end of the stroke.
re=0
function not enabled.
re=1
function enabled.
Connect the current feed +/-24V of both the transmitter and receiver of the photo-
electric cells of the open gate detector output (SCA).
By activating the function
fcm
(magnetic limit stop)= activates the operation of the magnetic limit stop.
fcm=0
fcm=1
function enabled.
26
ttca
) - CLOSING - STOP.
time).
function not enabled.
ttca
(if activated and greater than 3 secs) is
2p=1
function enabled: at each START impulse, the
al
re
, the
one cannot be activated.
ca=1
).
trel
ttca
auto-
time).