Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Franklin Electric Co., Inc.
Oklahoma City, OK 73157-2010
www.lg-outdoor.com
E N G L I S H
ENGLISH
EN
This instruction sheet provides you with the information required to
safely own and operate your product. Retain these instructions for
future reference.
The product you have purchased is of the highest quality workman-
ship and material, and has been engineered to give you long and
reliable service. This product has been carefully tested, inspected,
and packaged to ensure safe delivery and operation. Please exam-
ine your item(s) carefully to ensure that no damage occurred during
shipment. If damage has occurred, please contact the place of pur-
chase. They will assist you in replacement or repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
PRODUCT.
KNOW
THE
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF
AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD
RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE.
SAFETY GUIDELINES
WARNING: Your pump is an electrical product and caution should
be used when handling the pool cover pump or its electrical cord.
Small children or pets may require restraining devices to prevent
them from entering wet areas surrounding the pump or its power
supply connections.
1. This product is provided with a three-prong grounding plug, to
reduce the risk of electrical shock. When pump is in operation,
make sure it is properly connected to grounded outlet.
2. Never pump chemicals or corrosive liquids with this pump. This
could damage the integrity of the enclosure and cause an elec-
trical short.
3. Do not run this pump dry. Running this pump without water
may damage the integrity of the enclosure and cause electrical
short.
4. If service is required, proceed carefully. The pump and surround-
ing areas may be covered with water. Never plug or unplug the
device while standing on wet or damp surfaces. If necessary,
remove power at the breaker panel or have certified electrician
remove power before attempting to service. Serious or fatal
shocks could result if proper procedures are not followed:
a. Disconnect the power at the main electrical service box, by
switching the appropriate circuit breaker or removing fuse. In
applications where screw type fuses are used, remove only
with one hand while other hand or torso are free from contact
with anything. Do not stand in water and do not touch any
other conductive surfaces.
b. Remove pump cord plug only after the power to the supply
outlet has been removed. See Service Instructions before
proceeding.
5. Remove pump when freezing conditions will cause water to
freeze. Freezing water may result in cracking or distortions and
could result in possible electrical short or sensor failure.
6. Never pump gasoline or other low flash point fluids with this
pump. Explosion or fire could result.
500-APCP
CAREFULLY
BEFORE
PRODUCT'S
APPLICATION,
SPECIFICATIONS
VOLTS
AMPS
WATTS
115
.8
45
CAPACITY SIZING INFORMATION
The 500 GPH performance was obtained through a one inch I.D.
tube, with friction losses neglected. Using a 5/8" garden hose, 50
feet long, reduces this performance to approximately 200 gallons
per hour due to friction losses in the garden hose. If your area
frequently has heavy rainfalls (one to two inches per hour), it may
be necessary to use one inch tubing (available in most pool supply
stores). The gallons of water a pool cover collects in a rainfall of one
inch per hour can be determined by multiplying cover length (feet)
x cover width (feet) x .6234. (NOTE: This is cover dimension, NOT
pool dimension)
Examples:
A 16' x 32' pool cover collects 319 gallons in one hour, in one-inch-
per-hour rain (16 x 32 x .6234 = 319).
A 20' x 40' pool cover collects 499 gallons in one hour, in one-inch-
per-hour rain (20 x 40 x .6234 = 499).
INSTALLATION
1. Be certain electrical outlet to be used meets the requirements
of the National Electric Code, as well as local electrical codes,
including grounding, and GFCI protection. Also verify that outlet
is properly sized and located for this pump. Your installation
may require a certified electrician or plumber. See ELECTRICAL
CONNECTIONS section.
2. If necessary, check your local plumbing codes to verify that final
installation will be in compliance with their requirements.
3. Remove the pump from the carton. Connect a garden hose to
the volute. Secure the discharge end of the hose so that it can-
not blow back onto the pool cover in high wind.
4. Gently lower pump onto the pool cover by holding the garden
hose. Be certain you do not pull the power cord plug onto pool
cover. It is recommended that two people position the pump.
One person should hold electrical cord plugs while second
person positions pump at desired location on pool cover.
Position the pump so that it remains upright to allow proper
switch operation. The pump is equipped with a 25', 18 AWG
power cord, and has a 3-prong, grounding-type attachment
plug. Once the pump is in position and proper electrical con-
nections have been made, the pump is ready for testing (see
ELECTRICAL CONNECTIONS section).
Sensors
Capteurs
Sensores
GALLONS PER HOUR
1'
3'
5'
7'
500
395
293
184
Fig. 1
9'
82
1
Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little Giant 500-APCP

  • Página 1 SPECIFICATIONS GALLONS PER HOUR VOLTS AMPS WATTS Franklin Electric Co., Inc. Oklahoma City, OK 73157-2010 500-APCP www.lg-outdoor.com [email protected] E N G L I S H CAPACITY SIZING INFORMATION The 500 GPH performance was obtained through a one inch I.D. tube, with friction losses neglected. Using a 5/8" garden hose, 50...
  • Página 2: Electrical Connections

    NOTE: Become familiar with the SAFETY GUIDELINES section. FRANÇAIS During the rainy season, you should check daily to see that your pump is functioning properly. Also, if you experience high winds, Cette feuille d’instructions vous fournit les informations nécessaires or excessive movement of the pool cover, be certain the power pour entretenir et faire fonctionner votre produit.
  • Página 3 WARNING AVERTISSEMENT CARACTÉRISTIQUES TECHNIQUES CONNEXIONS ÉLECTRIQUES AVERTISSEMENT GALLONS PAR HEURE VOLTS AMPERES WATTS AVERTISSEMENT : Toujours couper l’alimentation électrique avant de toucher à la pompe, à la sortie ou à la prise de courant lorsqu’il y a de l’eau à proximité. Le non respect de cette consigne peut causer des dommages et/ou des blessures graves.
  • Página 4 INFORMACIÓN SOBRE LA CAPACIDAD ESPAÑOL El rendimiento de 500 galones por hora se obtuvo con un conducto de una pulgada de diámetro interior, donde la fricción se consideró nula. Al Esta hoja de instrucciones le proporciona la información requerida para usar una manguera para jardín de 5/8 de pulgada y 50 pies de largo, el tener y operar de forma segura su producto.
  • Página 5 2. Se recomienda un circuito de ramal independiente. Se requiere una FUNCIONAMIENTO fuente de alimentación de 115 V de CA y 5 amperios. 3. Asegúrese que el nivel del agua nunca alcance la conexión eléc- trica. Bajo ninguna circunstancia se debe colocar la conexión en PELIGRO: El objetivo de la bomba es remover el exceso de agua sobre algún lugar donde el agua pueda alcanzarla o sumergirla.
  • Página 6 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT PROBABLE CAUSES • CAUSES PROBABLES CORRECTIVE ACTION • SOLUTIONS • SOLUCION DÉFECTEUX • CAUSES PROBABLES • PROBLEMA Debris built up on sensors. • Accumulation de débris sur le Remove screen (item 4) and clean sensors.
  • Página 7 Company. Franklin Electric Company, Inc. and its subsidiaries (hereafter “the Company”) warrants that the products accompanied by this 6. Any product that has been used for purposes other than those warranty are free from defects in materials or workmanship of for which it was designed and manufactured.
  • Página 8: Garantie Limitée

    Société à d’autres produits de la Société, et la modification non autorisée des produits de la Société. Franklin Electric Company, Inc et ses filiales (ci-après « la Société 5. Les produits endommagés par l’usure normale, les services ») garantit que les produits accompagnés de cette garantie sont habituels d’entretien et les pièces utilisées dans le cadre de ces...
  • Página 9: Garantia Limitada

    Compañía a productos de la Compañía, y la alteración no autorizada de productos de la Compañía. Franklin Electric Company, Inc y sus subsidiarias (en adelante “la 5. Los productos dañados por el desgaste normal, mantenimiento Compañía”) garantizan que los productos que están acompañados normal y las piezas utilizadas en conexión con dicho servicio o...
  • Página 10: Descargo De Responsabilidad

    más allá de aquellas expresadas en este documento. PÁRRAFO SERÁN RAZONABLEMENTE MITIGADOS HASTA DONDE SEA POSIBLE. ESTE PÁRRAFO DEBE TAMBIÉN APLICARSE A TODOS LOS DAÑOS QUE RESULTEN DE ESTA GARANTÍA Y RECURSO ESTÁN POR ENCIMA DE TODAS LAS CONDICIONES ESTABLECIDAS ANTERIORMENTE LAS OTRAS GARANTÍAS Y RECURSOS QUE SE INCLUYEN SIN EN LA SECCIÓN III Y (1) DEFECTOS EN PROTOTIPOS DE LIMITACIÓN, GARANTÍAS...
  • Página 12 Para partes, la reparación, o la ayuda técnica por favor póngase en contacto ....1.888.956.0000 www.lg-outdoor.com [email protected] 994748 - 08/2013 Rev. 001 © 2013 Franklin Electric Co., Inc.

Tabla de contenido