Fleck ELECTRONIC SXT Serie Manual De Uso página 18

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1 - VALVE OPERATION
1.2.2
Start a manual regeneration
There are 2 options to initiate a manual regeneration:
A) Press and release the button
The icon
stop flashing.
The regeneration will start at the set hour.
B) Press and maintain for 5 seconds the
1.2.3
Advance to the next regeneration cycle
To advance to the next regeneration cycle, press the
valve is already advancing to the next cycle.
1.3
PROGRAMMING
Caution: The programming has to be done only by the installer for the setting of the valve
parameters. The modification of one of these parameters could prevent the good functioning of
the device.
To enter the programming mode, the valve has to be in service. While in program mode, the valve
will continue to operate normally monitoring all information. The programming is stored in
permanent memory with or without line or battery backup power.
To enter the programming mode, press simultaneously
Press on the button
modify the displayed values.
17
.
will start flashing, to cancel the regeneration request press
in order to jump to the next stage. Use the
button, the regeneration will start immediately.
button. This will have no effect if the
and
for 5 seconds.
ELECTRONIC SXT
button, the icon will
and
buttons in order to
E
N
G
L
I
S
H
Tabla de contenido
loading

Productos relacionados para Fleck ELECTRONIC SXT Serie

Tabla de contenido