3. MOUNTING THE COLOUR CHANGER (accessory, part nr. 20105106)
This section only applies in case you bought the followspot and the colour changer
separately.
• Mount colour filters on the colour changer units. See relevant instructions supplied with
the colour changer.
• At the front of the followspot, slacken the 3 cross‐head black M4 screws (two at the top
angles, one at the bottom, left‐hand side angle) so that they remain inserted
approximately half‐way through.
• Position the colour changer unit on the front plate of the follow spot, making sure that the
colour levers are positioned on the right‐hand side of the follow spot when viewed from
behind and hang it to the previously positioned screws.
• Release the colour filters of the colour changer by pressing the black, flat lever in order to
have access to the screws
• Insert a Phillips screws driver at least 12cm long in each one of the holes provided at the
front of the colour changer and tighten each screw
• Ensure the colour changer unit is secure, and all three screws are tight.
4. MOUNTING THE IRIS DIAPHRAGM
The iris diaphragm supplied with the followspot has 20 leaves to size the beam from a maximum
aperture of 68mm to a minimum of 5mm. A black‐out iris diaphragm is available to special order.
• Using a Phillips screw‐driver remove the two cross‐head screws from the sides of the iris
plate.
• Slide the diaphragm in the gate area.
• Tighten the screws.
Important notice:
Use the front dowser to "cut off" the light should you require to have the lamp on with no beam
projecting on the stage.
FAILURE TO COMPLY WITH THE ABOVE NOTICE MAY CAUSE THE IRIS AND THE FOLLOWSPOT TO
SUFFER MAJOR HEAT DAMAGES AND WILL INVALIDATE THE PRODUCT WARRANTY
5. SHUTTER BLADES (accessory, part nr. R80852039 x 4)
Shutter blades are not supplied with the unit but are available as separate accessory. They are sold
as single items and relevant part number is 80852039, 4 are required.
Tel. +39 0376 771 777 – fax +39 0376 772 140 – email
[email protected] – web www.ldr.it
LDR Canto 1200msr FF 120V MK2 User's manual – 1.0
do not leave the iris closed for over 5 minutes while the lamp is on
Luci della Ribalta srl, Via Berna 14, 46042 Castel Goffredo (MN) Italy
5