TECHNICAL DATA / INSTALLATION
TOUCH Wi-Fi in combination with the electronic device MASTER Wi-Fi
conforms to standard EN13849-2 (2008) and when used with a RIB
electronic control panel it is a Class 2 protection device for protecting
persons/things from collisions caused by mechanical moving parts such
as automatic gates or doors. The obstacle is detected along the entire
length of the device axially and perpendicularly.
The TOUCH Wi-Fi strips can be positioned anywhere without needing to
use electrical wire. The WiFi system (made up of a TOUCH Wi-Fi and
MASTER Wi-Fi) operate at a frequency of 868,3 MHz.
The MASTER Wi-Fi card communicates constantly with the TOUCH Wi-Fi
strips and always signals collisions or malfunctions.
Each TOUCH Wi-Fi has its own internal ID code that distinguishes it from
the other devices.
The WiFi system is an active security system because it constantly verifies
proper functioning of the TOUCH Wi-Fi devices and battery condition.
When using RIB electronic control panels you can run auto-tests on the
system.
With RIB actuators, RIB electronic control panels having the auto-test
function and RIB safety devices you can create an installation that
conforms to the European Directives and Norms in force.
After completing the system, you must make sure it conforms to standard
EN13241-1.
RIB shall not be liable for any damages caused by improper, incorrect or
unreasonable use of the product.
ATTENTION:
If you remove the power of the MASTER Wi-Fi for a long time,
the TOUCH Wi-Fi safety strips and the NOVA Wi-Fi photocells will
exhaust faster than normal the charging of their batteries. Keep the
MASTER Wi-Fi always properly fed to ensure a period of three years
for the batteries-life, as stated by RIB.
If for instance, the power to the system is cut off every night, the
photocells and the safety strips will regularly and constantly search
for the MASTER Wi-Fi without finding it. Therefore, the life span of
the batteries may be reduce to less than one year.
Any possible modification of the device, or of the configuration of the same
cannot be carried out without the clear authorization by the manufacturer
or, by the local authorized dealer.
The installer of the safety device must make sure that the end user know
the following:
- That the safety devices must be made known to all appropriate people.
- That the passages to reach the devices must be kept clear from any
obtsacle.
- About the procedures for cleaning so to avoid the dangerous building
up of material.
- The possible details for a restart of the system after an emergency or
accidental stop caused by the control system.
Any modification of the project or, of the configuration of the device,
without discussing it first with the manufacturer or with the local autorized
dealer can cause dangerous situations.
E
LECTRICAL CONNECTIONS
BAT
Alkaline batteries 3 x 1.5V (type AA code ACG9519)
SW2
Microswitches for combination and identification
J3
Terminals for connecting to mechanical strip contact
S2 PROG. TX
Programming pushbutton
DL1 (red)
Radio transmission signal
DL1
SW2
BAT
14
14
14
14
S2
J3
Tabla de contenido