Brush Removal
For the location of the parts used in the following procedures
see
Figure 14 on page 12
1 Disconnect the line cord from the power source
2 Lay the motor on its side with the brush cap (6) facing up
3 Use a 1/2 in 6-sided socket to unscrew the plastic brush
cap (6) from the motor half
4 The brush spring (5) will pop out Carefully remove the
brush spring by gently pulling on the spring
5 Repeat these steps for the opposite side
Brush Replacement
N
OTEE:
Brushes should be replaced in pairs
1 Inspect and replace damaged O-rings
2 Lubricate the O-ring prior to cap installation
3 Align the new brush (5) with brush holder Insert the
new brush
4 Push the spring into the holder as you screw the brush
cap back into the housing
N
OTEE:
The O-ring must be on the brush cap before you
screw the cap into the housing
5 Torque the brush cap (6) to 35 in lb
6 Repeat these steps for the opposite side
Filter Replacement
1 Pull the old filter down from the housing with
your fingers
2 Place the new filter (2) in the housing, tapered side up
See
Figure 14 on page 12
ELECTRIC VIBRATOR HEAD
SERVICE & MAINTENANCE
I
MPORTANT
Service the vibrator head after every 50 hours of operation for
trouble-free running on the job.
When servicing, always replace the hex driver, the seals and
the bearings, or bushing for 750-D & 750-EH heads
See
Electric Vibrator Head Assembly Drawings and Parts Lists on
page 15
All heads are equipped with seals at the flexible shaft end
and contain oil The seals serve a double purpose; to keep the
oil in the head and to keep the grease from the flexible shaft
out of the head
1 Hold the nose end in a vise and unscrew the end cap
counterclockwise with a chain wrench or a good pipe
wrench See
Figure 15
December 2018
2 Pull the eccentric rotor assembly out of the housing If the
bearings are stuck and you have difficulty removing them
from the housing, screw the end cap partly back into the
housing and bounce the head and cap down on a block
of wood in order to loosen the bearings from their seat,
then pull out the rotor assembly See
N
OTEE:
Hexagon driver has left hand threads
3 Flush the rotor assembly and housing with solvent and
wipe all parts clean Replace bearings, seals and hex
driver Maintain concentric alignment of the hex driver
with respect to the rotor shaft Refill with proper amount
of Wyco No 514-O non-foaming vibrator oil See
3 on page 14
equivalent to threads on both ends of rotor
VBR-UM-00043-EN-06
Electric Vibrator Head Service & Maintenance
Figure 15: End cap removal
Figure 16
Figure 16: Bearing Removal
Apply Loctite 545 adhesive/sealant or
Table
Page 13