• When the lights buttons are pressed, they should switch on.
3. Wait for the water temperature to reach the value set in the heater. Must be adjusted to the desired aquarium temperature
using the special knob. It is advisable to periodically check the water temperature, to ensure that a constant temperature is
maintained.
4. Proceed with adding any fish according to your own experience and complying with the "good practice" regulations for
aquariums.
VI. OPERATING AND CLEANING
EVERY WEEK:
a. Clean the inside of the aquarium glass panels with a magnetic brush (not included) to remove the patina of algae (Fig. 11).
b. Clean the LED lighting system protection with a sponge or a wet cloth (Fig. 12).
c. Check the water level. If it is too low, top it up to the required level with water at about the same temperature as the water in
the aquarium.
d. Check the water temperature using the immersion thermometer provided.
EVERY MONTH:
a. Replace the Newa Cobra filter cartridge choosing among the NEWAQUA media filter cartridges range.
EVERY 3 MONTHS:
a. Rinse the foam cartridge using the aquarium water, so that the bacterial colonies are preserved.
b. Clean the bottom of the aquarium by gently sucking up any deposited sediment. It is advisable to use the NEWA Pgr gravel
cleaning set. This operation should be done with great care in order not to uproot any plants or leave any roots uncovered.
c. Remove any deposits from the rotor and the pump impeller.
VII. TROUBLESHOOTING
If installation has been carried out correctly and the electrical accessories are operating normally, it is unlikely that any
technical problems will arise. If they should, consult an installer specialised in electrical appliances or contact the aquarium
product dealer to make a careful check or to replace the aquarium.
FAULTS
The cover does not remain
properly closed.
The lighting system are not
in operation
The water temperature
does not reach the set
levels
CAUSES
The cover does not remain properly closed.
The perimeter of the support is not
horizontal.
The lighting system is not connected to the
electrical socket
A temporary black out
The lighting system is not operating
correctly
The heater is not connected to the
electrical socket
The pump is clogged due to dirt or wear
and tear on the rotor
The heater is not operating correctly
SOLUTIONS
Apply specific pads on a movable part or along
the perimeter of the support, making it finally
completely horizontal (Fig. 14).
Contact your local dealer
Connect the plug to the electrical socket
---
Contact your local dealer
Connect the plug to the electrical socket
Carry out maintenance on the pump.
Contact your local dealer
15