NOTE: Continue to release steam for long time, when pump adds water into boiler,
soleplate will stop to release steam for short time, almost 10secs.
DRY IRONING
Connect the appliance to the mains supply, press the switch button(7), then select the desired
temperature by turning the thermostat knob(4).Wait until the iron heating indicator light (2) goes off,
indicating that the desired temperature has been reached.
For dry ironing it is not necessary to press the steam button (3).
FILLING THE TANK
Thanks to the self-filling function, there is no longer any need to stop and wait while the boiler
fills up again.
When the water in the boiler is at minimum level, the pump is automatically activated which fills
the boiler once again.
If you hear the loud feed-water sound when you ironing, it means there is no water in the water
tank (14).Press the switch button (7) and cut down the power. After fill the water tank (14), then
press the switch button (7) again, go on ironing.
To keep on working, simply restore the water level in the self-refilling tank as described in the
"Preparation for use" paragraph.
PUTTNG THE APPLIANCE AWAY
First ensure that the appliance has cooled down completely.
Empty the water tank(14).
It is not necessary to drain the boiler after ironing.
Steam line (5) and power cord (9) could be receipt into the wire groove (12) and line box (10).
LOCKING IRON
To lock the iron it must be set on the rear part of the rest mat (Fig11).
NOTE: make sure to firmly hook the iron to prevent it falling accidentally.
CARE OF YOUR VAPORELLA
Before attempting any maintenance operation, always disconnect the appliance from the mains.
To clean the body of the appliance, simply use a moist cloth. Do not use solvents or detergents
which may harm the body material.
Always keep the surface the ironing plate perfectly clean. To clean it, just wipe the cold surface
with a damp cloth. The appliance must not be cleaned with descaling agents.
Do not iron over zippers, hooks, rings, etc; as these may scratch the plate.
When you have finished ironing. Place the iron correctly on its stand. Ensure that there are no
traces of water under the plate, as these may cause stains.
Store the appliance in a dry place
PERIODIC CLEANING OF THE BOILER
· To maintain optimum performance, clean the boiler every 10/20 uses depending on the amount
of limestone in the water.
· Disconnect the appliance and let it cool down for at least 2 hours.
· After the appliance refrigeration enough put up one side of the cleaning valve (11), forced to
rotate counterclockwise the cleaning valve (Fig.5) (do not lie flat the appliance when you open
the cleaning valve, otherwise the water will leakage).
CAUTION! Never attempt to open the cleaning valve (11)while the boiler is under pressure.
CAUTION: do not pour more than 200ml water into the boiler. Pour water slowly, being careful
not to let it overflow, as this could damage the appliance.
· Rinse out the boiler and pour the water away into the sink or into a container for collecting dirty