Connections And Settings - Vimar Elvox 692D Instrucciones Instalador

Ocultar thumbs Ver también para Elvox 692D:
Tabla de contenido
Télécharger le manuel d'instructions sur le site www.vimar.com
EN
Description
Type 692D is a passive floor distributor. The distributor can be housed inside
a junction box or on DIN rail. The SI632 wiring diagram refers to a video door
entry installation with one cable riser and floor distributor. Other configurations
can be found in the instructions supplied with the entrance panels or electronic
units or in the Two-Wire manual.
Characteristics
The maximum current for each output is 700mA (can support simultaneous ac-
tivation of two monitors in parallel).
Operating temperature + 5 / + 40 °C.
Dimensions (Width x Height x Depth): 60x82x21 mm

Connections and settings

Connection of output 1A and 1B is necessary for the installation to function correctly.
If lines 2A - 2B, 3A - 3B, 4A - 4B are connected, then it is necessary to remove jumpers T2,T3, T4 respectively. If they are not used, leave
jumpers T2, T3, T4 inserted. If the cable riser continues to the OUT terminal, remove the TOUT jumper. On the last 692D connected to the
riser (OUT terminal is not used), the TOUT jumper must be inserted on 100 if using Elvox cable, or 50 if using CAT5 twisted pair cable.
Legend: terminals and connections
IN
Two-Wire cable riser input.
OUT
Two-Wire cable riser output.
1A - 1B
Output to interphone/monitor. Must always be used (connected).
2A - 2B
Output to interphone/monitor. If not connected see description of T2.
3A - 3B
Output to interphone/monitor. If not connected see description of T3.
4A - 4B
Output to interphone/monitor. If not connected see description of T4.
TOUT
3-pole pin-strip. The jumper must be removed if the cable riser continues to the OUT terminal. It must be inserted
on 100 (default) or 50 if the 692D is the last distributor in the chain.
T2
2-pole pin-strip. With interphone or monitor connected to terminals 2A and 2B, the jumper must be removed. If
nothing is connected on the terminals, leave the jumper inserted.
T3
2-pole pin-strip. With interphone or monitor connected to terminals 3A and 3B, the jumper must be removed. If
nothing is connected on the terminals, leave the jumper inserted.
T4
2-pole pin-strip. With interphone or monitor connected to terminals 4A and 4B, the jumper must be removed. If
nothing is connected on the terminals, leave the jumper inserted.
EN
Area serigrafia
Risultato finale
Serigrafia
3