ÉPIX™ Drive 642 QRG
Product Maintenance
To maintain optimum performance and minimize wear, you should clean this
product frequently. Usage and environment are contributing factors in
determining the cleaning frequency.
As a rule, clean this product at least twice a month. Dust build-up reduces light
output performance and can cause overheating. This can lead to reduced light
source life and increased mechanical wear.
Cleaning the ÉPIX™ Drive 642:
1.
Unplug the product.
2.
Wait until the product is at room temperature.
3.
Use a vacuum (or dry compressed air) and a soft brush to remove dust
collected on the external vents and accessible internal components.
4.
Clean all external surfaces with a mild solution of non-ammonia glass cleaner or
isopropyl alcohol.
5.
Apply a solution directly to a soft, lint-free cotton cloth or a lens cleaning tissue.
Wipe any dirt or grime to the outside edge of the surface. Gently polish the
surfaces with the lint-free cotton cloth or lens cleaning tissue until they are
free of haze and lint. Always dry the external surfaces carefully after cleaning
them.
Replacing the Fuse
1.
Disconnect this product from power.
2.
Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove the blown fuse and replace with a good fuse of the same type and
rating.
4.
Screw the fuse holder cap back into place and reconnect the power.
16
EN