Truper BOS-1/2LM2 Manual De Instrucciones página 19

Ocultar thumbs Ver también para BOS-1/2LM2:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION, USE AND MAINTENANCE
Unit Installation
1. Inspection of the well
1.1 Check the well diameter. Before buying and installing the pump
check if the internal diameter of the well complies with minimal
measures of our deep well submersible pump.
1.2 Wash the interior of the well. If the well is new remove objects
and mud. Use an air compressor or an old submersible pimp. when
the water inside the well complies with the pumping standards,
then, install the pump into the well.
1.3 Check the water in the well. Check if the water quality and
temperature comply with the conditions described for the pump.
2Insert a rope through the pump suspension eyelets. If the depth is less
than 98.4 ft, the rope shall be water and UV rays resistant. Otherwise,
the rope may get damaged due to the pump vibration.
When depth is more than 98.4 ft, fix it with steel wire.
WARNING
Do not use the power cable or the discharge pipe to
lift and support the pump.
3. Set the discharge pipe using a wrench to secure the connection.
4. Slowly, put in the pump in the well and keep the pump upwards. fix
the cable in the pipe using adhesive tape every 6.5 ft . Double check
the cables are not pressed against the well wall during the movement
of the pump because the cable may get damaged.
6
Power
Start Up Control
Cable
Box
Adhesive Tape
Static Water
Dynamic Water
Level
Minimum
Level 19.6"
Water
Suction
Installation Warnings
1. During the pump descent process, it if gets stuck do not keep on
forcing it. This prevents it to get blocked and damage the pump.
2. Determine the pump depth underneath the surface with regards of
the mud contents and the well condition. Do not set the pump onto the
mud. The distance between the pump and the bottom of the well shall
not be lower than 3.2 ft
3. The distance of the submerged pump at the dynamic water level shall
be smaller than 3.2 ft . Otherwise the pump may get damaged because
it runs idle.
4. If the pump is installed too low, use a valve in the pipes outside the
well to control the flow rate and protect it from tripping with the motor
control box because the flow rate is too low.
5. Connect the motor ground line correctly to prevent an electric
discharge due to electric leak.
Install the pump as illustrated.
Check Valve
Level
More Than 3.2 ft
Valve
Base Level
Suspension
Rope
Discharge
Pipe
Submersible
Pump
Tabla de contenido
loading

Tabla de contenido