Important!
When using the equipment, a few safety pre-
cautions must be observed to avoid injuries and
damage. Please read the complete operating
instructions and safety regulations with due care.
Keep this manual in a safe place, so that the in-
formation is available at all times. If you give the
equipment to any other person, hand over these
operating instructions and safety regulations as
well. We cannot accept any liability for damage
or accidents which arise due to a failure to follow
these instructions and the safety instructions.
1. Safety regulations
The corresponding safety information can be
found in the enclosed booklet.
Caution!
Read all safety regulations and instructions.
Any errors made in following the safety regula-
tions and instructions may result in an electric
shock, fi re and/or serious injury.
Keep all safety regulations and instructions
in a safe place for future use.
2. Layout and items supplied
2.1 Layout (Fig. 1/2)
1. Handle
2. Spindle lock
3. Guard hood
4. Operating switch
5. Safety lock-off
6. Locking screw for depth stop
7. Depth stop
8. Additional handle
9 . Vacuum extractor unit adapter
10. Guide roller
2.2 Items supplied
•
Open the packaging and take out the equip-
ment with care.
•
Remove the packaging material and any
packaging and/or transportation braces (if
available).
•
Check to see if all items are supplied.
•
Inspect the equipment and accessories for
transport damage.
•
If possible, please keep the packaging until
the end of the guarantee period.
Anleitung_MF_1300_SPK7_1.indb 14
Anleitung_MF_1300_SPK7_1.indb 14
GB
Important!
The equipment and packaging material are
not toys. Do not let children play with plastic
bags, foils or small parts. There is a danger of
swallowing or suff ocating!
•
Original operating instructions
•
Safety instructions
3. Proper use
This equipment is designed for cutting channels
for pipes and cables in masonry walls.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains voltage: ............................... 230 V ~ 50 Hz
Power input: ............................................ 1320 W
Idling speed: ......................................... 9000 rpm
Max. wheel diameter: ............................. 125 mm
Mounting hole: ...................................... 22.2 mm
Channel depth: .....................................8 - 30 mm
Channel width: .....................................8 - 26 mm
Protection class: ...........................................II /
Weight: .......................................................4.8 kg
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
sound pressure level ..................... 92,8 dB(A)
pA
K
uncertainty ............................................. 3 dB
pA
L
sound power level ..................... 103,8 dB(A)
WA
K
uncertainty ............................................. 3 dB
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
- 14 -
30.05.12 08:33
30.05.12 08:33