SPRAY PATTERN/PROBLEM POSSIBLE REASON
Improper spray pattern
Improper spray pattern
Improper spray pattern
1)One side of air cap
is clogged.
2)Dirt on one side of
fluid nozzle.
1)Loose air cap/dirty
seal.
2)One side of air cap
is clogged.
3)Dried material on
one side of fluid
nozzle.
1) Atomization air
pressure is set too
high.
2)Material too thin;
fluid adjustment
turned in too far.
3)Fan pattern open
too far.
24
SOLUTION
Remove air cap and soak in
solvent, then blow air
through until clean. Wipe
off nozzle tip using a rag
moistened with thinner. To
clean holes, use a broom
straw or toothpick. Never try
to detach dried material with
a sharp tool.
1)Tighten air cap.
2)Remove air cap and soak
in solvent, then blow air
through until clean. Wipe
off fluid nozzle using a rag
moistened with thinner. To
clean holes, use a broom
straw or toothpick. Never
try to detach dried material
with a sharp tool.
1)Reduce atomization air
pressure.
2)Open fluid adjustment
knob.
3)Partially close pattern
adjustment knob.