TURNING THE OVEN ON:
1.
Open the oven door
2.
Press and turn the knob "A" (pic .4-8) of the thermostatic valve
from position " " to " " keeping it pressed.
3.
At the same time, press the piezoelectric igniter "B" (pic. 2-8)
several times, to light the pilot flame.
4.
After the flame has lit, keep the knob pressed for roughly 10
seconds (count to 20); so the thermocouple heats up and keeps the
safety valve open.
5.
Check the ignition through the hole in the inspection cover "I" (pic
.7)
Turn off the gas shut-off cock installed upstream of the appliance.
Malfunctions are not always caused by the quality of the components
used. These appliances are manufactured using top quality components.
Failures may be caused by dust and dirt in the operating components.
Unauthorised persons should never attempt to repair the appliance or carry out maintenance. Tampering with the appliance voids
the warranty!
Before the unit is delivered to the user, the following checks must be
carried out.
THERMAL CAPACITY
Check that the type of gas supplied and the pressure correspond to the
ones indicated on the plate. If they don't, the unit must be converted or
adapted. In this case please refer to the paragraph: "Conversion or
Adaptation".
Check that the right nozzles have been installed.
Refer to the nozzle table T1 section Specifications and check that
the nozzles indicated in the table are the same as those installed on the
unit.
For an additional check of thermal capacity, verify the gas consumption
by means of the volumetric method: light the burner and after
approximately 10 minutes (operating conditions) check that the gas flow
(in m
3
/h or in kg/h) corresponds to the one indicated in nozzle table T1
section specifications.
Turning the gas oven on and off
What to do if the unit is not going to be used for a long time
Operational checks
6.
Now set the knob to the desired temperature.
The burner has a safety valve that cuts off the gas
supply if the flame should accidentally go out.
TURNING THE GAS OVEN OFF:
Turn the knob to position " " pressing it slightly so it goes past the
stop at the minimum position.
Clean the unit thoroughly following the instructions and dry it carefully.
Malfunctions
In any case, if you suspect the presence of anomalies, ALWAYS CLOSE
the gas shut-off cock and inform the authorised after-sales service.
APPEARANCE OF THE FLAME AND PRIMARY AIRFLOW
The flame should be blue and there should be no yellow dots in it; it
must be stable at its base.
If the colour of the flame tends to be yellowish , it means that the
primary airflow is not adjusted properly. If there's too much primary air,
the flame will be short and will tend to burn above the burner.
The appearance of the flame must also be checked 15 minutes after the
appliance has been running at full power. The flame must remain stable
even when passing quickly from minimum to maximum.
INSTRUCTIONS FOR THE USER
The user must be trained on the correct use and functions of the
appliance. We would like to point out that any alterations made in the
room where the unit is installed could influence the amount of air used
for combustion: for this reason the function of the unit must be checked
again. When these checks have been done, test the unit for leaks.