9.
Reattach the lanyard to the cotter ring and mounting bracket.
Verify that it is securely attached to both the cover and the
mounting bracket.
10. Route wires through the 1/2" NPT threaded openings into the
SelecTone unit in accordance with national and local electrical
and fire codes. Wire size depends upon the operating current
and the distance from the power source.
See the next sections for instructions on installing the speaker
connector card and UTM module, and wiring the speaker.

Installing the UTM Universal Tone Module

MISWIRING/ELECTRICAL SUPERVISION — Property damage,
serious injury, or death could occur if independent conductors
are terminated together; both wires of the same polarity must
be used as two separate connections. NFPA 72 requires that
the wires be terminated independently to provide electrical
supervision of the connection.
SHOCK HAZARD — To avoid electrical shock hazards, do not
connect wires when power is applied. Failure to heed this
warning may cause serious injury or death.
For details, refer to the instructions for the Model UTM Universal
Tone Module, doc. No. 2561101.
To install the UTM module in the speaker:
DO NOT DAMAGE SEALING SURFACES — Property damage,
serious injury, or death could occur if the machined sealing
surfaces are damaged on this product. To maintain the
effectiveness of the explosion-proof enclosure, be careful
to avoid damaging the machined sealing surfaces of cover
and housing.