Type approvals
The GROHE Red boiling water storage heater must be
installed with the safety assembly provided.
The boiling water storage heater may only be operated
together with an original GROHE Red boiling water fitting.
Application
The GROHE Red boiling water fitting supplies boiling water in
addition to hot and cold tap water. Boiling and mixed water
flows into the GROHE Red fitting through separate pipes and
flows out through two separate areas of the mousseur.
The boiling water storage heater is designed to heat and store
drinking water in pressurised systems. The boiling water
storage heater is suitable for connection to a mains system
with a maximum water pressure of 0.8 MPa (8 bar).
It must not be connected to hot water.
Safety notes
This device is not intended for use by persons
(including children) with physical, sensory or mental
impairments or a lack of experience or knowledge in
using devices of this type.
Children must be supervised to ensure that they do
not play with the device.
Prevent danger resulting from damaged power
supply cables. In the event of damage, the boiling
water storage heater must be replaced by the
manufacturer or its customer service department or
an equally qualified person.
The mains plug provided (type EF plug) is suitable for
use with Schuko (CEE 7/4) sockets.
Caution, risk of scalding. Escaping water is boiling
hot. Never touch the end of the spout in order to
swivel the spout as it becomes extremely hot.
• The boiling water storage heater must be connected to
a permanent power supply with earth wire.
• Installation is only possible in frost-free rooms.
• The boiling water storage heater is only suitable for
indoor use.
• The boiling water storage heater must be placed in an
upright position.
• The boiling water storage heater and plug must not be
directly or indirectly sprayed with water when cleaning.
• The boiling water storage heater must not be opened.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
If the boiling water storage heater is to be drained (for any
reason), the safety assembly of the boiling water storage
heater must be removed. Invert the boiling water storage
heater and allow the water to run out.
However, we strongly advise against draining the boiling
water storage heater. There is a significant risk of
damaging the boiling water storage heater.

Technical data

Boiling water storage heater electrical data:
• Connection:
Wall socket with earth wire, protected
• Voltage supply:
• Power consumption:
• Standby power loss (switched on):
• Standby power loss (switched off):
• Type of protection:
Sanitary data:
• Boiling water storage heater capacity:
• Flow pressure:
– min.
– recommended
• Operating pressure:
• Test pressure:
• Flow rate at 0.3 MPa (3 bar) flow pressure
- Mixed water:
- Boiling water:
• Boiling water temperature
The actual temperature may differ slightly due to different
ambient pressures
• Heating time from 10 °C to 100 °C:
• Available storage heater volume at 100 °C:
• Available storage heater volume at 60 °C:
• Max. chlorine value:
• Water connection at storage heater:
• Water connection at fitting:
Boiling water from storage heater
A filter system with water softener must be used in regions with
a carbonate hardness exceeding 12° KH.
An ion exchanger must additionally be installed in the supply
line for hardness values exceeding 14° KH, see Replacement
parts, fold-out page I, Prod. no.: 40 438.
The relevant water supplier can provide information on the
carbonate hardness and chlorine value.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This work
must be carried out in accordance with the
regulations according to IEC 364-7-701-1984
(corresponding to VDE 0100 Part 701) as well as
all national and local regulations.
• Extension cables are not permitted between the electrical
socket and boiling water storage heater connection.
via a 16 A fuse
230 V AC / 50 Hz
2100 W
15 W
1 W
IPX4
4 l
0.05 MPa (0.5 bar)
0.1 – 0.5 MPa (1 – 5 bar)
max. 0.8 MPa (8 bar)
1.6 MPa (16 bar)
approx. 10 l/min
approx. 3.7 l/min
100 °C
approx. 15 min
3 l/min
11 l/min
100 mg/l
Cold water
Cold water from service valve
Hot water from service valve