OPERATION MODES:

By pressing the
key, various operation modes may be selected: FROST PROTECTION, STORAGE HEATER, EMITTER,
ECOMBI MANUAL or ECOMBI AUTOMATIC.
1 - FROST PROTECTION MODE:
To select this mode press the
be 7º C. the appliance will maintain this temperature through convector operation. Storage heater will be off in this case.
2 – STORAGE HEATER MODE:
To select this mode press the
"АС" stands for STORAGE HEATER in Spanish. "4.0" would be the charge control position set to position 4.
As in a standard storage heater equipped with a 5- position charge control, charging settings in ECOMBI go from 0
(minimum charge) to 5 (maximum charge):
5.0 = charge 100% (during all the reduced rate time)
4.5 = 90%
4.0 = 80%
3,5 = 70%
3.0 = 60%
2.5 = 50%
i
While ECOMBI is charging (electric consumption) a small red dot will appear between the A and the C in the display.
DEFERRED CHARGING:
This function in ECOMBI allows optimizing the energy management and consumption. If in an off-peak period of 8 hours, it is
only necessary to charge at 50%, this is 4 hours, this function will make the effective charging period the last 4 hours during the
off-peak period. This means that ECOMBI will be fully charged at the end of the charging period.
In order to enable / disable this option please go to "General Settings" part in this manual and change P6 setting as ON / OFF.
PROTECTION FOR EXCESS OF TEMPERATURE IN THE ROOM:
In order to achieve maximum savings and avoid unnecessary energy consumption, if , during the charging period ,the
temperature in the room exceeds the temperature set up in ECOMBI for that room, then the charging will be interrupted until
the temperature in the room decreases by 1ºC.
3 –EMITTER MODE:
This operation mode is used when it is necessary to heat the room temporarily and there is no need for storage heating.
Press the
key several times until the message
"Е" stands for EMITTER.
"21.5" stands for the set up temperature in ºC.
Emitter will operate until the temperature in the room reaches 21,5ºC, then, it will maintain the temperature.
If needed, it is possible to change the set point temperature by using the keys
changing in steps of 0,5ºC.
i
Small red dot at the very right part of the display will show that the convector heating element is working at that moment.
Pressing simultaneously keys
device.
There can be a temperature difference between this sensor and a normal thermometer set up in a wall room. This is because
temperature is different at different heights in the room. The one at the floor is normally lower. User can adjust the sensor so
that different thermometers show the same temperature. For this you can go to General Settings part and modify the sensor
reading according to P5 setting.
key several times until the message
key several times until the message
and
will display room temperature taken from the sensor at the bottom of the
is displayed. The set up temperature will
is displayed.
2.0 = 40%
1.5 = 30%
1.0 = 20%
0.5 = 10%
0.0 = 0%
is displayed.
and
19
. Temperature value will be
Tabla de contenido