Supply power wire A:
EG
Multipolar electric wire. Size and length of the suggested electric wire are showed on table "electrical data". The wire must
be Mod. H05VV-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between the fixing point
and the terminals allows the straining of the conductors L, N before that of the grounding. For the models KPA/KPAV122R5
the power supply wire connections is Mod. Y, in case of damage, please contact the Service centre.
Supply power wire B:
Multipolar electric wire. Size and length of the suggested electric wire are showed on table "electrical data". The wire must
be Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between the fixing point
and the terminals allows the straining of the conductors L, N before that of the grounding.
Connecting wire C (with ground conductor):
Multipolar electric wire; size and length of the suggested electric wire are showed on table "electrical data". The wires have
not to be lighter than Mod. H07RN-F (according to CEI 20-19 CENELEC HD22).
Connecting wire D (without ground conductor):
Multipolar electric wire; size and length of the suggested electric wire are showed on table "electrical data". The wires have
not to be lighter than Mod. A07RN-F (according to CEI 20-19 CENELEC HD22).
Cavo di alimentazione A:
I
Cavo elettrico multipolare; la sezione e la lunghezza del cavo elettrico consigliato sono indicate in tabella dati elettrici. Il cavo
deve essere del tipo H05VV-F (secondo CEI 20-19 CENELEC HD22). Assicurarsi che la lunghezza dei conduttori fra il punto
di fissaggio del cavo ed i morsetti sia tale che i conduttori attivi si tendano prima del conduttore di messa a terra. Per i modelli
KPA/KPAV122R5 il collegamento del cavo di alimentazione è di tipo Y, qualora fosse danneggiato, per la sostituzione rivolgersi
al Centro Assistenza.
Cavo di alimentazione B:
Cavo elettrico multipolare; la sezione e la lunghezza del cavo elettrico consigliato sono indicate in tabella dati elettrici. Il cavo
deve essere del tipo H07RN-F (secondo CEI 20-19 CENELEC HD22). Assicurarsi che la lunghezza dei conduttori fra il punto
di fissaggio del cavo ed i morsetti sia tale che i conduttori attivi si tendano prima del conduttore di messa a terra.
Cavo di collegamento C (con conduttore di terra):
Cavo elettrico multipolare; la sezione e la lunghezza del cavo elettrico consigliato sono indicate in tabella dati elettrici. Il cavo
non deve essere più leggero del tipo H07RN-F (secondo CEI 20-19 CENELEC HD22).
Cavo di collegamento D (senza conduttore di terra):
Cavo elettrico multipolare; la sezione e la lunghezza del cavo elettrico consigliato sono indicate in tabella dati elettrici. Il cavo
non deve essere più leggero del tipo A07RN-F (secondo CEI 20-19 CENELEC HD22).
F
Câble d'alimentation A:
Câble électrique multipolaire: la section et la longueur du câble électrique recommandé sont indiquées dans le tableau
"Données électriques". Le câble doit être de type H05VV-F (selon CEI 20-19 CENELEC HD22).
Assurez-vous que la longueur des conducteurs entre le point de fixation du câble et le bornier soit telle que les conducteurs
actifs (Phase - Neutre) se tendent avant le conducteur de mise à la terre (pour permettre aux conducteurs actifs Phase -
Neutre de se débrancher avant le conducteur de terre si le câble d'alimentation est tiré accidentellement). Pour les modèles
KPA/KPAV122R5 le raccordement du câble d'alimentation est de type Y; en cas de câble endommagé, adressez-vous au
Service Après-Vente pour le remplacement.
Câble d'alimentation B:
Câble électrique multipolaire: la section et la longueur du câble électrique recommandé sont indiquées dans le tableau
"Données électriques". Le câble doit être de type H07RN-F (selon CEI 20-19 CENELEC HD22).
Assurez-vous que la longueur des conducteurs entre le point de fixation du câble et le bornier soit telle que les conducteurs
actifs (Phase - Neutre) se tendent avant le conducteur de mise à la terre (pour permettre aux conducteurs actifs Phase -
Neutre de se débrancher avant le conducteur de terre si le câble d'alimentation est tiré accidentellement).
Câble de raccordement C (avec mise à la terre):
Câble électrique multipolaire: la section et la longueur du câble électrique recommandé sont indiquées dans le tableau
"Données électriques". Le câble doit être de type H07RN-F minimum (selon CEI 20-19 CENELEC HD22).
Câble de raccordement D (sans mise à la terre):
Câble électrique multipolaire: la section et la longueur du câble électrique recommandé sont indiquées dans le tableau
"Données électriques". Le câble doit être de type A07RN-F minimum (selon CEI 20-19 CENELEC HD22).
22