STEP 6
INSTALL THE SYSTEM (CON'T)
Attach device to
discharge pipe using
hose clamps provided
Figure E
For wall mount
use 4.5 in. center
to center
Figure F
b. Connect the dual float sensor to the jack located on
the bottom of the device. (Figure B) Secure the dual
float sensor on the discharge pipe at the height you
want the alarm to activate using the hose clamp
provided. Fasten loose sensor and pump wiring to the
PVC pipe with the supplied mounting straps. Do not
allow wires to hang in the way of the primary pump
float or dual float sensors. Do not mount the dual float
sensor near an inflow pipe where water could splash
and give a false alarm. (Figure G)
Reverse view
Figure G
Do not allow electrical wires to obstruct
the primary pump float or dual float sensors.
Failure to secure the wires MAY impede the float and sensors and
result in water damage (see Figure G). Use above a completely
enclosed sump pit.
c. Plug the device into a GFCI (Ground Fault Circuit
Interrupter) outlet and power the unit on. (Step 2)
d. Once the status light turns solid green this device
is ready to receive text messages from your cellular
phone. (Figure H) In the next step, you will program the
device by sending it text message commands from
your cell phone.
4
a. Using your cellular phone, create and send a text
b. It is recommended to add contact numbers for
between Phone 1 and the next digit, e.g., Phone1_5557654321. The
word "{space}" and brackets should NOT be entered. If entered
incorrectly, you may not be able to send and receive text alerts
which MAY result in water damage.
Float
mounted
away from
inlet pipe
c. If you are successful in adding emergency contacts,
Ridge Tool Company
Solid
green
light
Figure H
STEP 7
ENTER EMERGENCY CONTACTS
message to the AdvanTEXT device number that you
saved in step 5. Type the following command:
Phone1{space}10 digit phone number. (Figure I)
Phone1, Phone2, and Phone3. In case of an
emergency alert, if one of the phone numbers are
out of network range, service has been interrupted or
disconnected, or the phone is off, it will NOT receive
an alert text notification. The device will send alerts to
all of the phone numbers that have been saved to
Phone1, Phone2, and Phone3 entries.
The reference to "{space}" throughout this
manual indicates a space in the numbers
This number will be saved to Phone1 or position #1. It is
necessary to type the set up as shown in the diagram
including spaces where indicated. Otherwise, set up may not
be successful.
Do NOT enter a "1" in front of the area code.
EXAMPLE CELL PHONE SCREEN:
Adding emergency contacts
Phone1 5557654321
Phone1{space}<10 digit phone number>
Figure I
the device will chirp twice and you will receive a text
message to the phone number you just entered.
Receipt of the text messages takes approximately 30
seconds after the device chirps. (Figure J) You can
repeat this process with two additional phones, using
Phone2, and Phone3 commands. See troubleshooting
section if this step is not successful.