Bio+ LX 00-02 Manual De Instalación Y Mantenimiento página 32

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

5.6.
Opening of the side doors. CAUTION! (WE MUST UNPLUG THE STOVE BEFORE PERFORMING THIS
OPERATION).
Remove two screws on each side of the stove, which are located on the front of the liner.
5.7.
Cleaning the fireplace.
In addition to daily cleaning carried out with great attention, the following items must be cleaned:
 Heat exchanger pipes. By activating the drawers of the rake. If you have a LX or VX model, remove the
top plate of the fireplace as indicated in section 5.1.
 Burn pot.
 Burn pot support.
 Ash box.
 Screws of Mobile parts.
 Air entrance pipe.
5.8.
Cleaning of the exhaust circuit of the stove, cleaning outlets and collector. Always with the stove unplugged.
(Very Important).
Remove side doors and the lining of the stove.
You must remove the side outlets, enter the wire brush and move it through the entire surface in order to
remove all the ash attached to the walls of the gas chamber. This operation must also be performed with the
front cleaning outlet.
As indicated in drawing 13 you can access to the lateral and lower cleaning outlet, which must be thoroughly
cleaned, since the correct operation of the stove will depend on its cleaning.
In the case of the lateral outlets, you must be aware that there is one on each side of the stove, in addition to
the core outlet located under the ash box.
Front-top cover.
Side cover.
Registry cleaning points.
It is recommendable to calculate the frequency with which you clean the outlet cleaning considering the
hours of operation, thus avoiding ash saturation.
Once you clean the walls of the stove, you must be sure that the cleaning outlet is securely closed, since the
proper operation of the stove depends on this cleaning.
5.9.
Cleaning of the exhaust circuit of the stove, extractor's collector.
For an optimal cleaning of the extractor's collector, it is recommended to dismantle the extractor itself in
order to have full access to this zone for a better cleaning. Once the extractor is dismantled, clean it with a
dry brush and be careful with the turbine and structure.
In the LX model the convection chamber plates must be removed.