Tips And Recommendations; Technical Data - SOMFY Sunilus io Guia De Instalacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Sunilus io / Sunilus screen io

8. TIPS ANd RECOMMENdATIONS

8.1. Questions about the Sunilus io / Sunilus screen io?
Observations
The awning does
The wiring is incorrect.
not work.
The motor is in heat protection mode.
An incorrect cable has been used.
The Somfy io control point battery is weak.
The control point is not compatible.
The Somfy io control point used has not been
programmed into the motor.
The awning stops
The crown is incorrectly positioned.
too soon.
The end limits have been incorrectly set.
8.2. Replacing a lost or broken Somfy io control point
Refer to the corresponding guide.
8.3. Restoring the original configuration
This reset deletes all the control points, all the sensors,
all the end limits settings and resets the motor's direc-
tion of rotation and favourite position (my). However, the
advanced functions setting ("Back impulse") are kept.
Apply the double power cut only for the motor to be
reset!
Set the awning to the halfway position (if possible).
1)
Cut the power supply off for 2 seconds.
2)
Switch the power supply back on from 5 to 15
3)
seconds.
Cut the power supply off for 2 seconds.
4)
Switch the power supply back on: the awning makes a
5)
movement for several seconds.
If the awning is in the upper or lower end limit position
it will make a brief movement.
Press and hold the PROG button: the awning will make
6)
a first movement, and repeat it a few moments later. The
motor is configured with the factory settings.
Repeat the procedures in the chapter "
-

9. TECHNICAL dATA

Radio frequency
Power supply
Operating temperature
Protection rating
Maximum number of connected io control points
and io sensors
Safety level
8
Possible causes
Commissioning".
868-870 Mhz, io-homecontrol® triband bi-directional
Solutions
Check the wiring and modify it if necessary.
Wait until the motor cools down.
Check the cable and ensure it has 3 leads.
Check if the battery is weak and replace it if
necessary.
Check for compatibility and replace the control
point if necessary.
Use a programmed io control point or program
this io control point.
Fit the crown correctly.
Readjust the end limits
1
5 sec.
3
ON
15 sec.
5
ON
6
230 V ~ 50 Hz
- 20 °C to + 70 °C
IP 44
9
Category I
Copyright © 2010 Somfy SAS. All rights reserved.
2
OFF
2 sec.
4
OFF
2 sec.
my