8.12
Size 8 ACU 601 (160.0...400.0 kW, 690 V)
Type
ACU 601
Size
Output, motor side
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-term overload current (1 s)
Output voltage
Protection
GB
Rotary field frequency
Switching Frequency
Output, braking resistor (extern)
Min. Brake resistance
Recommended Brake resistance
(U
= 770 V)
dBC
Input, mains side
6)
Mains current
7)
Mains voltage
Mains frequency
8)
Fuses
9)
Fuses as per UL
in preparation
Mechanical
Dimensions
Weight approx.
Ingress protection rating
Connection terminal
Form of assembly
Ambient conditions
Energy dissipation
(2 kHz Switching Frequency)
Coolant temperature
Storage temperature
Transport temperature
Relative humidity
If required by the customer, the switching frequency may be increased if the output current is reduced at the same time.
Comply with the applicable standards and regulations for this operating point.
10)
Output current
Frequency inverter nominal power
160 kW
200 kW
250 kW
315 kW
355 kW
400 kW
1)
Power reduction with torsional frequencies below 10 Hz
2)
Only with torsional frequencies above 10 Hz
3)
depending on switching frequency
4)
Reduction of switching frequency possible on certain conditions
5)
As an option, the frequency inverter of this size is available without internal brake transistor.
6)
Rated value with recommended motor power, 400V mains voltage and mains inductance U
7)
Note, that in addition to the AC 3x 525V connection a connection of AC 3x 400 V is required, see chapter 4.3.
8)
Semiconductor fuses recommended (in example Bussmann Type 170M)
9)
For UL-compliant fusing, the specified fuses must be used.
10)
Maximum current in continuous operation
84
-51
P
kW
160
I
A
180
eff.
1)
I
A
270
eff.
2)
I
A
330
eff.
U
V
eff.
-
-
f
Hz
f
kHz
5)
R
Ω
3.00
R
Ω
5.00
I
A
160
U
V
f
Hz
I
A
250
Type
HxWxD mm
m
kg
120
-
-
2
A
mm
-
-
P
W
3200
T
°C
n
T
°C
L
T
°C
T
-
%
2 kHz
305
380
475
595
645
735
Quick Start Guide ACU
-53
-55
-57
8
200
250
315
230
280
350
350
420
530
420
510
630
Maximum input voltage, three-phase
Short circuit / earth fault proof
3)
±500 Hz
4)
2, 4, 8
3.00
3.00
1.80
5.00
5.00
3.00
200
250
320
690 (reduced for UL: 600)
50 (60)
315
350
450
1067 x 439 x 375
120
120
140
IP20 (EN60529)
up to 2 x 240
Vertical
3950
4500
5500
-25 ... 45 (3K3 DIN IEC 721-3-3)
-25 ... 55
-25 ... 70
15 ... 85, not condensing
Switching Frequency
4 kHz
305
380
475
595
645
735
=4%
K
-59
-61
355
400
400
450
600
675
720
810
1.80
1.80
3.00
3.00
360
410
500
550
140
140
6250
6900
8 kHz
305
380
475
595
645
735
02/15