3. Identification plate
European Version CE
www.drenopompe.it
Via Umbria, 15 - Monselice (PD) Italy
Type
kW
Hz
3
V.
6
Hm
9
CL.IS.F IP 68 Year:
12
11
*the -EX acronym indicates that the pump is ATEX certified
INTERPRETATION OF THE NAME PLATE (ATEX marking strings)
1
1 EC Mark
2 Number of notified body
3 ATEX certified product symbol
4 Group II
5 Category 2, zone 1 or 2
6 G = Gas
7 Explosion proof enclosures
16
0477
II 2 G Ex db c IIB T4 X
S/N
1
R.p.m.
4
A.
7
Q l/sec
°C
14
2013
13
3
2
0477
N° CE certificate
EUM1 11 ATEX
17
0528 X
2
5
8
10
Kg
15
10 Flow rate (litres / second)
11 Insulation class
12 Year of production
13 Maximum submersion
14 Maximum operating temperature
15 Weight
16 Standard of reference
19 Certificate number
II 2 G db c IIB T4 X
4
5
5
7
8 Construction safety
Electric construction intended for locations with
9
explosive atmosphere other than mines
10 T4 = 135°C
Electric pump protected by a remote switch capable
of interrupting the power supply, installed in a safe
11
location. In case of tripping of at least one of the thermal
protectors installed in the windings.
- 29
1 Electric pump code*
2 Serial number
3 Rated power P2
4 Frequency
5 Revolutions per minute
6 Voltage
7 Absorption
8 Power factor
9 Head (meter)
9
10
11
8