PCB Fault
3 04
Too many resets
3 05
PCB Fault
Display
Description
3 06
PCB Fault
3 07
PCB Fault
COMMUNICATION WITH PERIPHERAL UNITS
4 01
Mdm-Bus Com error
4 02
GPRS mdm error
4 03
Sim Card error
4 04
Mdm-PCB Com err
4 05
Mdm In1 error
4 06
Mdm In2 error
4 07
Room Sensor Open Circuit
IGNITION AND DETECTION
5 01
No fl ame detected
5 02
Flame Sensed with Gas Valve Closed
5 04
Flame lift
5 P1
1st Ignit Failed
5 P2
2nd Ignition Failed
5 P3
Flame lift
AIR INLET / FLUE GAS EXHAUST
6 01
Fumes Overfl ow
6 02
6 04
Low fan speed
6 07
APS on FAN off
6 10
Exchanger Probe Open Circuit
6 12
Fan Error
6 P1
APS late closing
6 P2
APS close-open
Restoring operation
The boiler is protected from malfunctions by means of internal checks performed by the P.C.B.,
which stops the boiler from operating if necessary. In the event of the boiler being shut off in this
manner, a code appears on the Clima Manager display which refers to the type of shut-off and the
reason behind it.
To restore normal boiler operation, press the Multi-functional reset button, which will restore the
optimal conditions. If this shutdown occurs frequently, contact an authorised Service Centre for
assistance.
IT GB
No Reset
No Reset
Reset
Restore
Reset
Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
Reset
No Reset
No Reset
No Reset
Reset
No Reset
Reset
Reset