5. OPERATION:___________________________________________________________________________________________________
5.1. System on stand-by
The system goes into "STAND-BY" when the "
electrolysis cell.
5.2. System configuration
The AstralPool Chlore Elite system can be reconfigured through a menu accessed from the control panel. The system has to be switched off,
as described in point 5.1, in order to access this menu. Once the system has been switched off, press the "-" [1] key for a few seconds until
the system information screen [11] displays "CONF". To enable selection of each menu option, keep the "SALT TEST" [9] key pressed for
approximately 1 second. Select the desired parameter using the "-" [1] / "+" [14] keys and validate by pressing the "SALT TEST" [9] key for
one second again (see Fig. 20). The configuration process enables you to establish the following operative parameters:
MODEL
SOFTWARE VERSION
POLARITY SWITCH
OUTPUT LEVEL CONTROL WHEN CLOSED COVER
COVER CONTROL INPUT ACTIVATION
ORP/RESIDUAL CHLORINE CONTROL INPUT
ACTIVATION
GAS DETECTOR ACTIVACION
EXTERNAL FLOW DETECTOR
(FLOW SWITCH)
ACTIVATION
(1)
WARNING: only use this mode for check tasks, for short periods of time, as it could damage the electrodes.
(2)
Factory defaults.
-
" [1] key is pressed until the "0%" light blinks. When this occurs, there is no production in the
Fig. 18
Elite 60
Switch every 2 hours
System may be configured to provide an output to cell in the range 10 ... 90% of its nominal
Deactivated
Deactivated (MANUAL)
Deactivated
Deactivated
Fig. 19
11
Elite 100
Shows software version (two digits)
(2)
Switch every 3 hours
(2)
capacity when the pool cover is closed.
Activated input when closed
(2)
contact
Activated electrolysis system when closed contact (AUTO)
Activated electrolysis system when flooded detector
Activated electrolysis system when closed contact
Elite 160
(1)
Switch every 2 minutes
Activated input when open
contact
(2)
(2)
(2)