INSTALLATION AND MAINTENANCE INSTRUCTIONS
MI-CZ6
Six Zone Interface Module
SPECIFICATIONS
Normal Operating Voltage:
Stand-By Current:
Alarm Current:
Temperature Range:
Humidity:
Dimensions:
Accessories:
Wire Gauge:
Maximum IDC Wiring Resistance:
External Supply Voltage
DC Voltage:
Ripple Voltage:
Current:
IDC:
BEFORE INSTALLING
This information is included as a quick reference installation
guide. Refer to the appropriate control panel installation manual
for detailed system information. If the modules will be installed in
an existing operational system, inform the operator and local au-
thority that the system will be temporarily out of service. Discon-
nect the power to the control panel before installing the modules.
This system contains static sensitive components. Always ground
yourself with a proper wrist strap before handling any circuits so
that static charges are removed from the body. The module hous-
ing should also be grounded.
NOTICE: This manual should be left with the owner/user of
this equipment.
M450-04-00
15-32 VDC
2 mA
40 mA (assumes all six LEDs solid on)
0°C to 49°C
10 to 85% Non-condensing
17.3cm H x 14.7cm W x 3.2cm D
Suitably grounded metallic cabinet
0.9mm2-3.25mm2
25 Ohms
18-28 volts power limited
0.1 volts RMS maximum
90mA per module
Supervised and power limited
Compatible Two-wire System Sensor Smoke Detectors for use with MI-CZ6
DET.
DETECTOR
MODEL
DET. ID
MANUFACTURER
1151
A
SYSTEM SENSOR
1451
A
SYSTEM SENSOR
1451DH
A
SYSTEM SENSOR
2151
A
SYSTEM SENSOR
2451
A
SYSTEM SENSOR
2451TH
A
SYSTEM SENSOR
5451
A
SYSTEM SENSOR
1100
A
SYSTEM SENSOR
1400
A
SYSTEM SENSOR
** 2100AT
A
SYSTEM SENSOR
2100B
A
SYSTEM SENSOR
2100D
A
SYSTEM SENSOR
2100S
A
SYSTEM SENSOR
2100TB
A
SYSTEM SENSOR
2100TD
A
SYSTEM SENSOR
2100TS
A
SYSTEM SENSOR
2300B
A
SYSTEM SENSOR
2300TB
A
SYSTEM SENSOR
2400
A
SYSTEM SENSOR
2400TH
A
SYSTEM SENSOR
* 2W-B
A
SYSTEM SENSOR
* 2W-TB
A
SYSTEM SENSOR
DH100LP
A
SYSTEM SENSOR
* Class B, Style B only
** No Accessory will be supported by 2100AT
GENERAL DESCRIPTION
The MI-CZ6 Six Zone Interface Module is intended for use in an
intelligent alarm system. Each module provides an interface be-
tween the intelligent alarm system and a conventional alarm sys-
tem loop. A common SLC input is used for all modules, and the
initiating device loops share a common supervisory supply and
ground. Otherwise, each monitor operates independently from the
others. Each module has its own unique address.
A pair of rotary code switches is used to set the address of the first
module from 01 to 94. The remaining modules are automatically
assigned to the next five higher addresses. Provisions are included
for disabling a maximum of two unused modules to release the
addresses to be used elsewhere. Each module also has panel con-
trolled by color LED indicators. The panel can cause the LEDs to
blink, latch on, or latch off.
BASE MODEL
B110LP, B401
B401, B401B
DH400
B110LP, B401
DH400, B401B, B401
B401, B401B
B401
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1
by Honeywell
Morley IAS Fire Systems
Charles Avenue,
Burgess Hill, West Sussex, RH15 9UF
MAX DET.
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
I56-2954-000