VOLTAGE RELAY
VOLT curr freq v/hz
27 Phase Undervoltage
59 Phase Overvoltage
27TN Neutrl Undervolt
59X Overvoltage
59N Neutral Overvoltage
59D Volt. Diff. 3rd Har.
CURRENT RELAY
volt CURR freq v/Hz
46 Neg Seq Overcurrent
50 Inst Overcurrent
50/27 Inadvertent Energing
50BF Breaker Failure
50DT Def. Time Overcurr
50N Inst Overcurrent
51N Inv Time Overcurrent
49 Stator Overload
51V Inv Time Overcurrent
87 Differential Overcurr
87GD Gnd Diff Overcurr
67N Res Dir Overcurr
FREQUENCY RELAY
volt curr FREQ v/hz
81 Frequency
81R Rate of Change Freq
81A Frequency Accum.
VOLTS PER HERTZ RELAY
volt curr freq V/HZ
24 Def Time Volts/Hertz
24 Inv Time Volts/Hertz
POWER RELAY
PWR lof fuse dist
32 Directional Power
LOSS OF FIELD RELAY
pwr LOF fuse dist
40 Loss of Field
V. T. FUSE LOSS RELAY
pwr los FUSE dist
60FL V. T. Fuse Loss
PHASE DISTANCE RELAY
pwr lof fuse DIST
21 Phase Distance
78 Out of Step
FIELD GROUND RELAY
FIELD stator sync
64B/F Field Ground
STATOR GROUND RELAY
field STATOR sync
64S Stator Ground
SYNC CHECK RELAY
field stator SYNC
25S Sync Check
25D Dead Volt
BREAKER MONITOR
BRKR trpckt ipslog
Set Breaker Monitoring
Preset Accumulators
Clear Accumulators
TRIP CIRCUIT MONITOR
brkr TRPCKT ipslog
Trip Circuit Monitor
IPS LOGIC
brkr trpckt IPSLOG
IPS Logic
CONFIGURE RELAY
CONFIG sys stat
Voltage Relay
Current Relay
Frequency Relay
Volts per Hertz Relay
Power Relay
Loss of Field Relay
V.T. Fuse Loss Relay
Phase Distance Relay
Field Gnd Relay
Stator Gnd Relay
Sync Check Relay
Breaker Mon Relay
Trip Ckt Mon Relay
IPSLogic Relay
SETUP SYSTEM
config SYS stat
Input Activated Profiles
Active Setpoint Profile
Copy Active Profile
Nominal Voltage
Nominal Current
V. T. Configuration
Delta-Y Transform
Phase Rotation
59/27 Magnitude Select
50DT Split-phase Diff.
Pulse Relay
Latched Outputs
Relay Seal-in Time
Active Input State
V.T. Phase Ratio
V.T. Neutral Ratio
V.T. VX Ratio
C.T. Phase Ratio
C.T. Neutral Ratio
NOTA: Dependiendo de cuales funciones sean adquiridas,
algunos menús pueden no aparecer.
Figura 3-3 Flujo del Menú Principal
Operación – 3
STATUS
config sys STAT
Voltage Status
Current Status
Frequency Status
V/Hz Status
Power Status
Impedance Status
Sync Check Status
Breaker Mon Acc Status
81A Accumulators Status
In/Out Status
Timer Status
Relay Temperature
Counters
Time of Last Power Up
Error Codes
Checksums
VIEW TARGET HISTORY
TARGETS osc_rec comm
View Target History
Clear Target History
OSCILLOGRAPH RECORDER
targets OSC_REC comm
View Record Status
Clear Records
Recorder Setup
COMMUNICATION
targets osc_rec COMM
COM1 Setup
COM2 Setup
COM3 Setup
Communication Address
Response Time Delay
Comm Access Code
Ethernet Setup
Ethernet IP Address
SETUP UNIT
SETUP exit
Software Version
Serial Number
Alter Access Codes
User Control Number
User Logo Line 1
User Logo Line 2
Clear Output Counters
Clear Alarm Counter
Date & Time
Clear Error Codes
Ethernet Firmware Ver.
Diagnostic Mode
EXIT LOCAL MODE
setup EXIT
3–5