Rotary Lifts Serie Instrucciones De Instalación página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

12. Locking Latch Cable
A) Install latch cable sheave and retaining
rings in upper slot of power unit column as
shown, Fig. 17.
B) Slip loop end of cable over end of shoulder
screw on right side latch control plate, Fig.
17.
C) Feed the other end of the cable through the
latch cable sheave slot making sure that
the cable is running under the bottom side
of the latch cable sheave and inside the
right column, Fig. 17.
D) Attach latch cable conduit guide brackets
to overhead as shown, Fig. 16a & Fig. 16b.
Always use the holes on the approach side
of the lift. HHCS should be in hole nearest
the center of the overhead, Fig. 16b.
E) Route cable up inside column and through
the latch cable guide, Fig. 16a & Fig. 18.
IMPORTANT
Using wire ties provided, tie off
cable guide to column extension as shown,
Fig. 16a. Guide must be attached in hole
closest to the outside edge of the column
on the NON-APPROACH side.
F) Continue routing cable to the left column
latch cable guide, Fig. 16a & Fig. 18, routing
the cable through the left column latch
cable guide, Fig. 16a.
IMPORTANT
Using wire ties provided, tie off
cable guide to column extension as shown,
Fig. 16a. Guide must be attached in hole
closest to the outside edge of the column
on the NON-APPROACH side.
G) Bring the cable down inside the left column
and feed the end of the cable through the
lower latch cable sheave slot so that the
cable is now back outside the column, Fig.
19.
H) Install latch cable sheave and retaining
rings in lower slot of non-power unit
column as shown, Fig. 19.
Attach Hose Clamps Here
Attach Latch Cable Conduit
Guide Bracket Here. Always
use two holes on approach
side of extension to attach bracket.
Attach to extension using
wire tie. Use hole closest
to OUTSIDE edge and on
NON-APPROACH side.
3/8"-16NC x 3/4" HHCS
and Flanged Locknut
I)
Route cable under the bottom side of the latch cable
sheave, Fig. 19.
J) At this point you MUST install the latch handle, jam
nut, and right column latch cover Fig. 17 & Fig. 20.
Install latch handle ball, Fig. 20.
K) Insert cable in cable clamp along one side, loop
around shoulder screw and back down, inserting
cable along other side of cable clamp, Fig. 19. Place
top back on clamp, barely tightening.
L) Next, pull the control plate down, Fig. 18 & Fig. 19, to
eliminate any clearance between the control plate slot
and the latch dog pin, Fig. 18.
M) Using Pliers, pull cable tight and secure the clamp
close to the shoulder screw. Tighten clamp.
Always put HHCS through hole
closest to center of overhead.
10
3/8"-16NC x 3/4" HHCS
and Flanged Locknut
Latch cable runs
along approach
side of overhead
1/4"-20NC x 1" HHCS
and Flanged Locknut
Cable Guide
runs UNDER
hydraulic hose
Fig. 16a
Fig. 16b

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Spoa10nbSpoa10Spo10Spoa7Lifts 500Lifts 700 ... Mostrar todo