Command and control devices
Button and/or selector key-switch (not supplied) with
OPEN-CLOSE (NO contact) function. Alternatively, from
function programming you can activate the OPEN-STOP-
CLOSE-STOP command. See function F7.
Button and/or selector key-switch (not supplied) with
CLOSE (NO contact) function.
Button and/or selector key-switch (not supplied)
with PEDESTRIAN OPENING (NO contact) function.
Alternatively, from function programming you can
activate the PARTIAL OPENING command. See function
F8.
Button and/or selector key-switch (not supplied) with
OPEN (NO contact) function.
Button (not supplied) with STOP function (NC contact). For
stopping the gate while excluding automatic closing. To resume
movement press the control button or use another control
device. See function F1.
- Marketed buttons.
- Optional key-switch selector, KEYSTAR item.
10 11 E TS 1 2 3 3P 4 5 7 CX CY
Fit the RXStar radio
board to control the gate
through a transmitter.
WARNING! Before fitting
the radio board, you MUST
CUT OFF THE MAINS
POWER SUPPLY and,
remove any batteries.
7 CX CY B1 B2 A B S1 GND