Left safety guide.
Right safety guide
Front cleaning registry.
Side cleaning registry.
It is recommendable to calculate the frequency with which you clean the outlet cleaning considering the
hours of operation, thus avoiding ash saturation.
Once you clean the walls of the stove, you must be sure that the cleaning outlet is securely closed, since the
proper operation of the stove depends on this cleaning.
5.8.
Empty the hopper to take remaining pellets out to avoid pellets absorb humidity.
5.9.
Cleaning of the pellets drop tube.
Use the brush provided by ECOFOREST to remove the dust until the end of the tube.
Cleaning brush.
Pipe of pellets fall.
5.10. Cleaning of the exhaust circuit of the stove, extractor's collector.
For an optimal cleaning of the extractor's collector, it is recommended to dismantle the extractor itself in
order to have full access to this zone for a better cleaning. Once the extractor is dismantled, clean it with a
dry brush and be careful with the turbine and structure.