Cabinet
• poor room condi ons
temperature
is too high or
• output air temperature is out-
too low
side the speci ed range
• the cabinet is defros ng.
• the capacitor or the evaporator
are freezing.
• the capacitor or the evaporator
are obstructed or dirty.
• the load is not distributed
evenly
Water leaks,
• cabinet drains are obstructed
bad smell
or damaged
• water collec on tray is sealed
incorrectly
• water collec on tray over ows • check wiring of evapora on heater
• lacking coupling between
cabinets in channel or sealed
incorrectly
Frost or ice
in the cabinet
• fans do not work
in the evaporator
• heaters broken
• Sdef probe detached
• air currents that alter the circu-
la on of refrigerated air
i
in all cases not described or where it is not possible to solve the problem by following these
direc ons call the nearest support centre
05060161 00 08-04-2015
• check the posi on of the cabinet inside the
store 13
• check the opera on of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and
restore the air ow direc on
• check that fan plenum is su cient and not
obstructed
• check the intake pressure that should com-
ply with rated speci ca ons
• check defros ng parameters
• check that the suc on line is not obstructed
• clean them 22.4
• load the goods in order (Fig.15)
• release the drains,
• repair or replace the drains
• seal it properly
• check the opera on of evapora on heater
• install and seal the joints
• check electrical connec ons.
• check the ven la on inside the store