DIP Switch Settings

O
8
7
6
5
4
3
2
1
DIP 1: LEDs operation
On: LEDs Enabled
Off: LEDs Disabled
DIP 2-3: Detection Sensitivity
Sensitivity
Low
Mid
Normal (Default)
Maximum*
* In maximum sensitivity sway recognition is
disabled to achieve maximum sensitivity

Microwave Adjustment

Adjust Microwave coverage area by using the trimmer on the PCB.

Walk test

Two minutes after applying power, walk test the protected area to verify
proper operation.
For installations on uneven surfaces slide the PCB inside the internal base to
the appropriate setting according to the desired height (1.0m, 1.5m, 2.2m,
2.7m) as printed on the bottom left corner of the PCB or use the standard
swivel accessory.
For reducing the detection range, slide the PCB up or tilt the swivel
down.

LEDs Display

LED
State
Steady
YELLOW
Flashing
Steady
GREEN
Flashing
Steady
RED
Flashing
Flashing (One
All LEDs
after another)
Notes:
1. DIP-Switch 1 should be in ON position to enable LED indications.
2. Only one LED is active at any one time. For example, in the case of both PIR and MW detection, either the
steady YELLOW LED or the steady GREEN LED is displayed (the first to detect), followed by the Alarm RED
3. In order to prevent the analysis of detection technologies such as PIR, Microwave, Active IR AM and
Proximity AM, set DIP Switch 6 (SW1) to ON. Only the red LED will be activated.
Factory Defaults
DIP2
DIP3
Off
Off
Off
On
On
Off
On
On
Description
Indicates PIR detection
Indicates Active IR AM (Anti mask) detection
Indicates MW detection
Indicates Proximity AM detection
Indicates ALARM
Indicates malfunctioned communication with ProSYS (BUS
mode only)
Unit initialization on power up
WatchOUT 315DT Installation Manual
DIP 4: Anti masking Sensitivity
On: High
Off: Low
DIP 5: Detector's optics
On: Barrier / Long range
Off: Wide angle
DIP 6: Red LED /3 LED
On: Red LED only
Off: 3 LEDs
DIP 7: Anti masking operation
On: Enabled
Off: Disabled
DIP 8: Proximity AM
On: Enabled
Off: Disabled
MIN MAX
PCB
1.00M
1.50M
2.20M
2.70M
7